7. Monitoring and Troubleshooting

TStatus: Contains the contents of the status events register. The status events register maintains a history of specific events that have occurred during an interval. Values include:

Y: Remote alarm indication signal (yellow alarm) received at the DSX-1 interface

L: Loss of signal detected at the DSX-1 interface

E: Excessive error rate threshold exceeded

F: Frame synchronization bit error detected

V: Line code violation detected

None: No significant events have occurred

Fields on this screen include:

Field . . .

Contains . . .

 

 

Current Interval Timer

The number of seconds which have elapsed in the current

 

15-minute interval. Maximum value is 900 seconds

 

(15 minutes). This counter is reset every 15 minutes.

 

When zero, the port is disabled.

 

 

Error Events Counter

A running total of CRC and OOF events. Range = 0–65535.

 

This counter is reset when the statistics are cleared.

 

When zero, the port is disabled.

 

 

Current Int

Performance data for the current 15-minute interval. When

 

blank, the port is disabled.

 

 

Interval xx

Historical performance data for up to 96 15-minute intervals

 

(24 hours) where the value of xx is from 01 to 96. When blank,

 

the port is disabled.

 

 

Worst Interval

Identifies the interval during which the most error events were

 

detected. When blank, the port is disabled.

 

 

Tot

A running total of the performance statistics.

 

 

7-16