7. Monitoring and Troubleshooting

Table 7-2. Self-Test Results Messages (2 of 2)

Message

What Message Indicates

What To Do

 

 

 

FPGA Failed

The Field Programmable

1. Reset the unit and try again.

 

Gate Array serving all ports

2. Call your service

 

failed.

 

representative for

 

 

G.703 Failed, Pt 1

The unit failed to loop data on

assistance.

 

the G.703 on Port n.

 

 

 

 

Memory

The unit failed memory data

 

Test n Fail

verification (Test 1) or

 

 

memory address verification

 

 

(Test 2).

 

 

 

 

Passed

No errors were detected.

No action is needed.

 

 

 

PLD Failed, Pt n

An error was detected in a

1. Reset the unit and try again.

 

Programmable Logic Device.

2. Call your service

 

 

TSI CPLD Fail

The Complex Programmable

representative for

 

Logic Device serving the

assistance.

 

Timeslot Interchanger failed.

 

 

 

 

TSI Fail

The Timeslot Interchanger

 

 

failed.

 

 

 

 

7-8