B. Standards Compliance for SNMP Traps

The tests that affect the enterpriseTestStart and enterpriseTestStop traps and the variable bindings depend on the interface. The specific tests and variable bindings are described in the following table.

 

enterpriseTestStart/Stop

 

 

Interface

variable bindings

Possible Cause

 

 

T

DSL Network

ifIndex (RFC 2863)

enterpriseTest Start – Any one

 

ifAdminStatus (RFC 2863)

of the following tests is active

 

on the interface:

 

 

 

 

ifOperStatus (RFC 2863)

Line Loopback

 

TifType (RFC 2863)

Repeater Loopback

 

ifTestType (RFC 2863)

Remote Line Loopback

 

– Send and Monitor 511

 

The following objects control tests

 

 

 

 

in SNMP-managed devices:

enterpriseTest Stop – No tests

 

– noTest(0) – Stops the test in

currently running on the

 

 

progress.

interface.

 

testLoopLLB(4) – Initiates a

 

 

 

 

Local Loopback.

 

 

 

testLoopRLB(5) – Initiates a

 

 

 

 

Repeater Loopback.

 

 

 

testSendMon511(6) – Initiates a

 

 

 

 

Send and Monitor 511 test.

 

 

 

testSendLLBUp(7) – Initiates an

 

 

 

 

LLB Up message to the remote

 

 

 

 

unit.

 

 

 

testSendLLBDown(8) – Initiates

 

 

 

 

an LLB Down message to the

 

 

 

 

remote unit.

 

 

 

 

 

DSX-1 or

ifIndex (RFC 2863)

enterpriseTest Start – Any one

G.703

ifAdminStatus (RFC 2863)

of the following tests is active

 

on the interface:

 

 

 

 

ifOperStatus (RFC 2863)

DTE Loopback

 

TifType (RFC 2863)

Telco Payload Loopback

 

ifTestType (RFC 2863)

T

(DSX-1 only)

 

enterpriseTest Stop – No tests

 

The following objects control tests

 

currently running on the

 

in SNMP-managed devices:

 

interface.

 

– noTest(0) – Stops the test in

 

 

 

 

 

progress.

 

 

 

testLoopDTLB(3) – Initiates a

 

 

 

 

DTE Loopback.

 

 

 

testLoopPLB(1) – A

 

 

 

 

Telco-initiated Payload

 

 

 

 

Loopback is active on the

 

 

 

 

interface (DSX-1 only).

 

 

 

 

 

 

 