Paradyne U8777, 8779 manual Self-Test Results Messages, Dte

Models: U8777 8779

1 182
Download 182 pages 21.75 Kb
Page 59
Image 59

7. Monitoring and Troubleshooting

Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of the System and Test Status screen.

Table 7-2. Self-Test Results Messages (1 of 2)

Message

What Message Indicates

What To Do

 

 

 

CPU Fail

The Central Processing Unit

1. Reset the unit and try again.

 

failed internal testing.

2. Call your service

 

 

CPU CPLD Fail

The Complex Programmable

representative for

 

Logic Device serving the

assistance.

 

Central Processing Unit

 

 

failed.

 

 

 

 

Data Path Fail, Pt n

The port shown failed to loop

 

 

data on the full data path test.

 

 

 

 

DeviceFailed

One or more of the unit’s

 

 

integrated circuits has failed

 

 

device-level testing.

 

 

 

 

DSL

The DSL framer for Ports

 

Framer x Fail

1–4 (Framer A) or

 

 

5– 8 (Framer B) failed.

 

 

 

 

DSL xcvr Fail, Pt n

The DSL transceiver failed

 

 

on Port n.

 

 

 

 

DSX-1 Failed, Pt n

The unit failed to internally

 

 

loop data on the DSX-1

 

 

Port n.

 

 

 

 

DTE

The DTE framer for Ports

 

Framer x Fail

1– 4 (Framer A) or

 

 

5– 8 (Framer B) failed.

 

 

 

 

DTE LIU x Fail

The DTE Line Interface Unit

 

 

for Ports 1–2 (LIU A),

 

 

3– 4 (LIU B), 5– 6 (LIU C), or

 

 

7– 8 (LIU D) failed.

 

 

 

 

EEPROM Fail

The unit failed Electrically

 

 

Erasable Programmable

 

 

Read-Only Memory

 

 

verification.

 

 

 

 

Failure xxxxxxxx

An internal failure occurred.

Record the failure code

 

(xxxxxxxx represents an

and contact your service

 

8-digit hexadecimal failure

representative.

 

code for use by service

 

 

personnel.)

 

 

 

 

8700-A2-GB20-40

May 2002

7-7

Page 59
Image 59