Paradyne 8779, U8777 manual Monitoring and Troubleshooting

Models: U8777 8779

1 182
Download 182 pages 21.75 Kb
Page 56
Image 56

7. Monitoring and Troubleshooting

Table 7-1. Health and Status Messages (2 of 4)

Message

What Message Indicates

What To Do

 

 

 

 

IBMC Not Supported

The Inband Management

1.

Disable the Inband

on MCP

Channel (IBMC) is enabled,

 

Management Channel.

 

but the MCP card does not

2.

Download the MCP with a

 

support Inband Management.

 

 

 

version of code that supports

 

 

 

inband management.

 

 

 

IP Mismatch, Pt n

The NTU and the LTU are

In a DSLAM-to-DSLAM

 

operating in different NMS

configuration, use the same

 

management modes: one is

software in the management

 

in IP Conservative mode and

cards of both DSLAMs.

 

one is not.

 

 

 

 

 

 

LOF at DSX-1,

An LOF (Loss Of Frame)

1.

Verify that the network cable

Pt n

condition has been detected

 

is securely attached at both

 

on the DSX-1 interface. LOF

 

ends.

 

is declared when an OOF

2.

Verify the unit’s line framing

 

state exists longer than 2.5

 

 

and line coding are

 

seconds.

 

 

 

compatible with the attached

 

 

 

 

 

 

equipment.

 

 

3.

Contact network provider.

 

 

 

 

LOF at G.703,

An LOF condition has been

1.

Verify that the network cable

Pt n

detected on the G.703

 

is securely attached at both

 

interface. LOF is declared

 

ends.

 

when any three consecutive

2.

Verify that the units line

 

frame synchronization bits

 

 

framing and line coding are

 

are incorrect, frames not

 

 

 

compatible with the attached

 

containing the frame

 

 

 

equipment.

 

alignment signal are received

 

 

 

 

 

with an error three times

3.

Contact network provider.

 

consecutively, or, for CRC-4

 

 

 

framing, CRC multiframe bit

 

 

 

alignment fails.

 

 

 

 

 

 

LOS at DSX-1,

An LOS (Loss Of Signal)

1.

Verify that the network cable

Pt n

condition has been detected

 

is securely attached at both

 

on the DSX-1 interface. No

 

ends.

 

signal is being received on

2.

Contact network provider to

 

Port n. LOS is declared when

 

 

troubleshoot the line.

 

175 consecutive zeros are

 

 

 

 

 

received.

 

 

 

 

 

 

LOS at G.703,

An LOS condition has been

1.

Verify that the network cable

Pt n

detected on the G.703

 

is securely attached at both

 

interface. No signal is being

 

ends.

 

received on Port n. LOS is

2.

Contact network provider to

 

declared when 175

 

 

troubleshoot the line.

 

consecutive pulse

 

 

 

 

 

transmissions are received

 

 

 

with no pulse transitions.

 

 

 

 

 

 

7-4

May 2002

8700-A2-GB20-40

Page 56
Image 56
Paradyne 8779, U8777 manual Monitoring and Troubleshooting