7. Monitoring and Troubleshooting

Viewing Network Error Statistics

The terminal unit maintains error statistics on the network DSL interface for each port.

To view Network Error Statistics, follow this menu selection sequence:

Main Menu StatusPerformance StatisticsNetwork Error Statistics

main/status/performance/net_error

 

Slot: 4:

 

Model: 87xx

Port: 2

NETWORK ERROR STATISTICS

Current Interval Timer: 002

Error Events Counter: 0034

-------------------------------------------------------------------------------

 

---ES

---

---SES

---

--FEBE--

-Complete-

 

Near

Far

Near Far

Near

Far

Near Far

Current Int:

000

 

000

000

000

000

000

Yes

No

Interval 01

000

000

000

000

000

000

Yes

Yes

Interval 02

000

 

000

000

000

000

000

Yes

Yes

Interval 03

000

 

000

000

000

000

000

Yes

Yes

Interval 04

000

000

000

000

000

000

Yes

Yes

Interval 05

000

 

000

000

000

000

000

Yes

Yes

Interval 06

000

 

000

000

000

000

000

Yes

Yes

Interval 07

000

000

000

000

000

000

Yes

Yes

Worst Interval: 24

 

09

14

08

18

18

 

 

Near Tot(valid):

00010

00000

00000

 

 

Far Tot (valid):

00010

00000

00000

 

 

-------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu

MainMenu Exit

PgUp

PgDn

ClrNear ClrFar

 

he following Network Error Statistics are collected for the selected port:

ES (Errored Seconds): Seconds during which one or more Cyclical

Redundancy Check (CRC) error events occurred. Maximum value is 900.

SES (Severely Errored Seconds): Seconds during which more than 320 or more CRC error events occurred. Maximum value is 900.

FEBE (Far-End Block Errors): Errors reported by the remote equipment.

TMaximum value is 900.

Complete: Whether the interval register contains data for all 900 seconds of the interval.

7-12