Polycom® RMX 1800 Administrator’s Guide
7-8 Polycom, Inc.
3Define the following parameters:
4Click OK.
The new SIP Factory is added to the list.
Table 7-3: New Factory Properties
Option Description
Display Name Enter the SIP Factory name that will be displayed.
The Display Name is the conferencing entity name in native language
character sets to be displayed in the Collaboration Server Web Client.
In conferences, Meeting Rooms, Entry Queues and SIP factories the
system automatically generates an ASCII name for the Display Name
field that can be modified using Unicode encoding.
English text uses ASCII encoding and can contain the most
characters (length varies according to the field).
European and Latin text length is approximately half the length of
the maximum.
Asian text length is approximately one third of the length of the
maximum.
The maximum length of text fields also varies according to the
mixture of character sets (Unicode
and ASCII).
Maximum field length in ASCII is 80 characters. If the same name is
already used by another conference, Meeting Room or Entry Queue,
the Collaboration Server displays an error message requesting you to
enter a different name.
Routing Name The Routing Name is defined by the user, however if no Routing
Name is entered, the system will automatically assign a new name
when the Profile is saved as follows:
If an all ASCII text is entered in Display Name, it is used also as
the Routing Name.
If any combination of Unicode and ASCII text (or full Unicode text)
is entered in Display Name, the ID (such as Conference ID) is
used as the Routing Name.
Profile The default Profile is selected by default. If required, select the
conference Profile from the list of Profiles defined in the MCU.
A new conference is created using the parameters defined in the
Profile.
Automatic
Connection
Select this check box to immediately accept the conference creator
endpoint to the conference. If the check box is cleared, the endpoint
is redirected to the conference and then connected.