Polycom® RMX 1800 Administrator’s Guide
19-26 Polycom, Inc.
13 Type the IP Address and the Community name of the manager terminal used to
monitor the MCU activity, and then click OK.
The Community name is a string of characters that will be added to the message that is
sent to the external Manager terminals. This string is used to identify the message
source by the external Manager terminal.
The new IP Address and Community name is added to the Trap Destinations box.
aTo delete the IP Address of a Manager terminal, select the address that you wish to
delete, and then click the Remove button.
The IP address in the Trap Destinations box is removed.
14 Click the Security tab.
User Name Enter the name of the user who is to have access to the trap.
3
Engine ID Enter an Engine ID to be used for the Trap.
This field is enabled when the Enable Trap Inform check box is
selected. If the Enable Trap Inform check box is cleared the
Engine ID of the Agent is used. The Engine ID is comprised of
up to 64 Hexadecimal characters.
Default: Empty
Security Level Select a Security Level from the drop-down menu.
Range: No Auth, No Priv; Auth, No Priv; Auth, Priv
Default: Auth, Priv
Authentication
Protocol
Enter the authentication protocol: MD5 or SHA.
The availability of the MD5 Authentication Protocol as a
selectable option is controlled by adding the
SNMP_FIPS_MODE System Flag to system.cfg and setting its
value. A value of YES means that MD5 will neither be displayed
as selectable option nor supported.
Range: YES/NO.
Default: NO.
Authentication Password
Privacy
Protocol
Enter the privacy protocol: DES or AES.
The availability of the DES Privacy Protocol as a selectable
option is controlled by adding the SNMP_FIPS_MODE System
Flag to system.cfg and setting its value. A value of YES means
that DES will neither be displayed as a selectable option nor
supported.
Range: YES/NO.
Default: NO.
Privacy Password
Table 19-14 SNMPv3 - Traps (Continued)
Field Description Versio n