Chapter 20-System Configuration Flags
Polycom, Inc. 20-9
3To modify a flag value, double-click or select the flag and click the Edit Flag button.4In the New Value field, enter the flag’s new value.5Click OK to close the Update Flag dialog box.6Repeat steps 2–4 to modify additional flags.
SESSION_TIMEOUT_IN_MI
NUTES
If there is no input from the user or if the connection is idle for
longer than the number of minutes specified by this flag, the
connection to the Collaboration Server is terminated.
Value: 0-999
0 - Session Timeout is disabled.
Default: 0
SIP_AUTO_SUFFIX_EXTEN
SION
Used to automatically add a suffix to a SIP address (To
Address) instead of adding it manually in the Collaboration
Server Web Client (SIP address) when the SIP call is direct-
dial and not through a Proxy.
Example:
Participant Name = john.smith
Company Domain = maincorp.com
SIP_AUTO_SUFFIX_EXTENSION flag value =
@maincorp.com
Entering john.smith will generate a SIP URI =
john.smith@maincorp.com
STAR_DELIMITER_ALLOWE
D
When set to YES, an asterisk “*” can be used as a delimiter in
Conference and Meeting Room dial strings.
The dial string is first searched for “'#' first followed by “*”.
Default: NO
TERMINATE_CONF_AFTER
_CHAIR_DROPPED
From Version 8.1, this flag’s functionality is replaced by the
Terminate Conference after Chairperson Drops check box
in the Profile - IVR dialog box.
In versions prior to 8.1, if YES, sets conferences to
automatically terminate if the Chairperson disconnects from
the conference. This takes effect only if the Conference
Requires Chairperson check box in the Conference Profile
Properties, IVR Tab, is selected.
Default: YES
Note: In order for the "Chairperson Exit" message to be
played this flag must be set to YES.
Table 20-1 System Flags – MCMS_PARAMETERS (Continued)
Flag Description