Polycom RMX 1800 Administrator’s Guide
B-6 Polycom, Inc.
Hot Backup: Paired MCU is unreachable.
Initialization of ice stack failed
Insufficient resources The number of resources in the license is higher than the actual system
resources.
Check the media cards or insert a media card.
Insufficient UDP Ports When defining fixed port, the number of defined UDP ports is lower than the
required ports.
Configure additional ports.
Internal System configuration during
startup
System configuration during startup.
Wait until Collaboration Server startup is completed.
Invalid System Configuration
IP addresses of Signaling Host and
Control Unit are the same
IP addresses of Signaling Host and Control Unit are identical.
Assign different IP addresses to the Signaling Host and Control Unit.
IP Network Service added
IP Network Service configuration modified IP Network Service was modified.
Reset the MCU.
IP Network Service deleted IP Network Service was deleted.
Reset the MCU.
IP Network Service not found IP Service not found in the Network Services list.
Configure the IP Network Service.
IPMC software upgrade in component
IPS 140 test result not received
LDAP TLS: Failed to connect to OSCP
responder
License not found Possible causes:
The Central Signaling component could not find the IP Services after
startup.
During Startup, the resources did not get the License required to utilize
their Units.
Possible action:
Configure IP service if not configure.
Reset the MCU.
Change the license
Management Network not configured Configure the Management Network.
Missing Central Signaling configuration Configure the central signaling.
Missing Central Signaling IP configuration
Table B-1 Active Alarms (Continued)
Alarm Code Alarm Description