Appendix B-Active Alarms
Polycom, Inc. B-9
SIP TLS: Failed to load or verify certificate
files
This alarm indicates that the certificate files required for SIP TLS could not be
loaded to the Collaboration Server. Possible causes are:
Incorrect certificate file name. Only files with the following names can be
loaded to the system: rootCA.pem, pkey.pem, cert.pem and
certPassword.txt
Wrong certificate file type. Only files of the following types can be loaded to
the system: rootCA.pem, pkey.pem and cert.pem and certPassword.txt
The contents of the certificate file does not match the system parameters
SIP TLS: Registration handshake failure This alarm indicates a mismatch between the security protocols of the OCS
and the Collaboration Server, preventing the Registration of the Collaboration
Server to the OCS.
SIP TLS: Registration server not
responding
This alarm is displayed when the Collaboration Server does not receive a
response from the OCS to the registration request in the expected time frame.
Possible causes are:
The Collaboration Server FQDN name is not defined in the OCS pool, or is
defined incorrectly.
The time frame for the expected response was too short and it will be
updated with the next data refresh. The alarm may be cleared
automatically the next time the data is refreshed.
The Collaboration Server FQDN name is not defined in the DNS server.
Ping the DNS using the Collaboration Server FQDN name to ensure that
the Collaboration Server is correctly registered to the DNS.
SIP TLS: Registration transport error This alarm indicates that the communication with the SIP server cannot be
established. Possible causes are:
Incorrect IP address of the SIP server
The SIP server listening port is other than the one defined in the system
The OCS services are stopped
Software upgrade in component
SSH is enabled
SWITCH not responding Check the Switch card.
System Cards MPM Plus mode are not
supported in Event mode
System configuration changed. Please
reset the MCU
System Configuration modified System configuration flags were modified.
Reset the MCU.
System resources of Audio ports usage
has exceeded Port Gauge threshold
System resources of Video ports usage
has exceeded Port Gauge threshold
Table B-1 Active Alarms (Continued)
Alarm Code Alarm Description