Polycom® RMX 1800 Administrator’s Guide
19-4 Polycom, Inc.
RMX Time
To ensure accurate conference scheduling, the MCU has an internal clock that can function
in standalone mode, or in synchronization with up to three Network Time Protocol (NTP)
servers.
Guidelines
NTP Version 4 is the only supported protocol.
If applicable, daylight saving adjustments must be implemented by the administrator
whether the MCU is in standalone mode or synchronized with NTP Servers.

Altering the clock

The MCU’s date and time can be set manually or enabled to synchronize with external NTP
servers.
To Alter the MCU Time:
1On the Collaboration Server menu, click Setup > RMX Time to open the RMX Time
dialog box.
2View or modify the following fields:
Table 19-2 RMX Time – Fields Properties
Field Description
GMT Date The date at Greenwich, UK.
Local Time The MCU’s local time settings, are calculated from the GMT Time and
the GMT Offset.
GMT Time The MCU’s current GMT Time settings.
Select the Up or Down arrows to alter the GMT Time on the MCU.