Appendix B-Active Alarms
Polycom, Inc. B-3
Error reading MCU time Failed to read MCU time configuration file ([status]).
Manually configure the MCU Time in the Collaboration Server Web Client or
RMX Manager Manager application.
eUserMsgCode_Cs_EdgeServerDnsFaile
d
eUserMsgCode_Cs_SipTLS_CertificateH
asExpired
eUserMsgCode_Cs_SipTLS_CertificateS
ubjNameIsNotValid_Or_DnsFailed
eUserMsgCode_Cs_SipTLS_Certificate
WillExpireInLessThanAWeek
eUserMsgCode_Cs_SipTLS_FailedToLo
adOrVerifyCertificateFiles
eUserMsgCode_Cs_SipTLS_Registration
HandshakeFailure
eUserMsgCode_Cs_SipTLS_Registration
ServerNotResponding
Event Mode Conferencing resources
deficiency due to inappropriate license.
Please install a new license
External NTP servers failure The MCU could not connect to any of the defined NTP server for
synchronization due to the remote server error or network error or
configuration error.
Change the configuration of the NTP server.
Failed to access DNS server Failed to access DNS server.
Failed to configure the Media card IP
address
Possible reasons for the failure:
Failure type: [OK Or Not supported.
Does not exist Or IP failure.
Duplicate IP Or DHCP failure.
VLAN failure Or Invalid: [status_Number].
Failed to configure the Users list in Linux The authentication process did not start.
Use the Restore to factory Defaults to recover.
Failed to connect to application server Possible reasons for the failure:
Failed to connect to application server:
Failed to establish connection to server, url = [url].
Failed to connect to recording device The MCU could not connect to the defined recording device due to
configuration error or network error.
Failed to connect to SIP registrar Cannot establish connection with SIP registrar.
Table B-1 Active Alarms (Continued)
Alarm Code Alarm Description