Chapter 16-IP Network Services
Polycom, Inc. 16-19
To modify the automatic LAN port configuration:
1On the Collaboration Server menu, click Setup > Ethernet Settings.
The Ethernet Settings dialog box opens.
The Collaboration Server has 2 LAN ports. You can select the speed and transmit/
receive mode manually for these ports.
2In the Speed column, click the drop-down arrow of the table entry to modify and select
the speed and the transmit/receive mode for each port:
When Auto (default) is selected, the negotiation of speed and transmit/receive mode
starts at 1000 Mbits/second Full Duplex, proceeding downward to 100 Mbits/second
Half Duplex.
Note: To maximize conferencing performance, especially in high bit rate call
environments, a 1Gb connection is recommended.
3 Click the OK button.
IP Network Monitoring
The Signaling Monitor is the Collaboration Server entity used for monitoring the status of
external network entities such as the gatekeeper, DNS, SIP proxy and Outbound proxy and
their interaction with the MCU.
To monitor signaling status:
1In the Collaboration Server Management pane, click Signaling Monitor ().
2In the Signaling Monitor pane, double-click Default IP Service.