Polycom® RMX™ 1800 Administrator’s Guide
21-2 Polycom, Inc.

Hardware Monitor Pane Tool bar

The following buttons appear in the tool bar of the Hardware Monitor:
Viewing the Properties of RMX 1800 Hardware Components
The properties displayed for the hardware components will vary according to the type of
component viewed. These component properties can be grouped as follows:
MCU Properties (RMX 1800)
Card Properties (DSP cards)
Supporting Hardware Components Properties (FANS, LAN, PWR)
Status The current status of the hardware component; Normal, Major, Critical,
Resetting, Diagnostics, or Empty.
Temperature Monitors the temperature of the hardware components; Normal, Major and
Critical.
Note: Critical condition invokes a system shut down.
Voltage The voltage threshold of the hardware component; either Normal or Major.
Table 21-2 Hardware Monitor Pane Tool Bar Buttons
Button Name Description
System Reset Resets and restarts the system. Resetting saves settings and
information that you changed in the system, i.e. IP Services,
etc...
System Shut Down Shuts down the system into a standby mode. When the user in
the RMX Manager/Client presses the System Shut Down (red) button
in the Hardware Monitor tool bar, the system should
enter a standby mode and the LED turns ON. Turn the system
OFF/ON to exit the standby mode.
Active Diagnostic
Mode
Activates Diagnostic mode. The system restarts and enter the
Diagnostic mode and you can perform tests to detect
malfunctions in the hardware component’s performance.
Note: Only Polycom Support can perform Diagnostic tests. For
more information, contact your Polycom Support.
Table 21-1 Hardware Monitor Pane Status Columns (Continued)
Field Description
No properties are provided for Power Supply (PWR). For more information, see the RMX 1800