Manuals
/
Brands
/
Computer Equipment
/
Switch
/
Q-Logic
/
Computer Equipment
/
Switch
Q-Logic
59042-07 A manual
1
1
206
206
Download
206 pages, 1.53 Mb
Simplify
0
59042-07 A
Page i
SANbox2-8c Fibre Channel Switch
Installation Guide
Firmware Version 4.2
Contents
Main
Page ii 59042-07 A
SANbox2-8c Fibre Channel Switch Installation Guide
Document Revision History
Release, Revision A, September 2004 Firmware Version 4.2 SANsurfer Switch Manager Version 4.02
Table of Contents
Section 1 Introduction
Section 2 General Description
Section 3 Planning
Section 4 Installation
Section 5 Diagnostics/Troubleshooting
Appendix A Specifications
Appendix B Command Line Interface
Glossary Index Figures
Tabl es
Section 1
Introduction
Intended Audience
Related Materials
New in this Release
Safety Notices
Sicherheitshinweise
Notes informatives relatives la scurit
Communications Statements
Federal Communications Commission (FCC) Class A Statement
Canadian Department of Communications Class A Compliance Statement
Avis de conformit aux normes du ministre des Communications du Canada
CE Statement
VCCI Class A Statement
BSMI Class A Statement
Laser Safety Information
Electrostatic Discharge Sensitivity (ESDS) Precautions
Accessible Parts
Pices Accessibles
Zugngliche Teile
General Public License
Preamble
Terms And Conditions For Copying, Distribution And Modification
Page
Page
Page
How to Apply These Terms to Your New Programs
Page
Technical Support
Availability
Train ing
Contact Information
Page
Section 2
General Description
Figure 2-1. SANbox2-8c Fibre Channel Switch
Chassis Controls and LEDs
Figure 2-2. Chassis Controls and LEDS
Maintenance Button
Resetting a Switch
Placing the Switch in Maintenance Mode
Chassis LEDs
Figure 2-3. Chassis LEDs
Over Temperature LED (Amber)
Fan Fail LED (Amber)
Heartbeat LED (Amber)
Input Power LED (Green)
Fibre Channel Ports
Figure 2-4. Fibre Channel Ports
Port LEDs
Figure 2-5. Port LEDs
Port Logged-In LED
Port Activity LED
Small Form-Factor Pluggable (SFP) Transceivers
Figure 2-6. SFP Transceiver
Port Types
Ethernet Port
Figure 2-7. Ethernet Port
Serial Port
Figure 2-8. Serial Port and Pin Identification
Power Supply and Fan
Switch Management
SANsurfer Switch Manager
SANsurfer Switch Manager Web Applet
Command Line Interface
SANsurfer Switch Manager Application Programming Interface
Simple Network Management Protocol
File Transfer Protocol
Section 3
Planning
Devices
Device Access
Soft Zones
Access Control List Hard Zones
Performance
Distance
Bandwidth
Latency
Multiple Chassis Fabrics
Optimizing Device Performance
Domain ID, Principal Priority, and Domain ID Lock
Common Topologies
Cascade Topology
Figure 3-1. Cascade-with-a-Loop Topology
Mesh Topology
Figure 3-2. Mesh Topology
Multistage Topology
Figure 3-3. Multistage Topology
Fabric Security
User Account Security
Fabric Services
Fabric Management
Section 4
Installation
Site Requirements
Fabric Management Workstation
Switch Power Requirements
Environmental Conditions
Installing a Switch
Figure 4-1. SANbox2-8c Fibre Channel Switch
Mount the Switch
Install SFP Transceivers
4 Installation Installing a Switch
59042-07 A 4-5
4.2.3
Connect the Workstation to the Switch
Figure 4-2. Workstation Cable Connections
Direct Ethernet RJ-45 Connection
Indirect Ethernet RJ-45 Connection
Serial RS-232 Connection
Configure the Workstation
Setting the Workstation IP Address for Ethernet Connections
Configuring the Workstation Serial Port
Page
Install the Management Application
SANsurfer Switch Manager
Page
SANsurfer Management Suite
SMS Installation for Windows
Page
SMS Installation for Linux
Page
SMS Installation for Solaris
Page
Start SANsurfer Switch Manager
Connect the Switch to AC Power
Page
Configure the Switch
Page
Cable Devices to the Switch
Install Firmware
Using SANsurfer Switch Manager to Install Firmware
Using the CLI to Install Firmware
Powering Down a Switch
Page
Section 5
Diagnostics/Troubleshooting
POST Diagnostics
Heartbeat LED Blink Patterns
Internal Firmware Failure Blink Pattern
System Error Blink Pattern
Configuration File System Error Blink Pattern
Page
Logged-In LED Indications
Figure 5-1. Logged-In LED
E_Port Isolation
Excessive Port Errors
Page
Chassis Diagnostics
Figure 5-2. Chassis LEDs
Over Temperature LED is Illuminated
Input Power LED Is Extinguished
Fan Fail LED is Illuminated
Recovering a Switch
Maintenance Exit
Maintenance Image Unpack
Maintenance Reset Network Config
Maintenance Reset User Accounts to Default
Maintenance Copy Log Files
Maintenance Remove Switch Config
Maintenance Remake Filesystem
Maintenance Reset Switch
Appendix A
Specifications
Fabric Specifications
Maintainability
Fabric Management
Dimensions
Electrical
Environmental
Regulatory Certifications
Appendix B
Command Line Interface
Logging On to a Switch
User Accounts
Working with Switch Configurations
Modifying a Configuration
Page
Backing up and Restoring Switch Configurations
Page
Commands
Page
Admin Command
Authority Syntax
Keywords
Notes
Examples
Alias Command
Authority Syntax
Keywords
Page
Config Command
Authority Syntax
Keywords
Notes
Examples
Config Command
59042-07 A B-13
Create Support Command
Syntax Examples
Page
Date Command
Firmware Install Command
Authority Syntax Examples
Hardreset Command
Help Command
Syntax Keywords
Examples
History Command
Syntax Notes
Examples
Hotreset Command
Syntax Notes
Image Command
Syntax
Keywords
Notes
Page
Image Command
B-24 59042-07 A
12. Wait for the unpack to complete.
image unpack command result: Passed
Examples
Lip Command
Passwd Command
Authority
Syntax Keywords
Examples
Ping Command
Syntax
Keywords
Examples
Ps Command
Ps Command
Displays current system process information.
Syntax Examples
Quit Command
Reset Command
Syntax
Keywords
Notes
Table B-4. Port Configuration Defaults
Table B-5. Port Threshold Alarm Configuration Defaults
Table B-6. Zoning Configuration Defaults
Table B-7. SNMP Configuration Defaults
Table B-5. Port Threshold Alarm Configuration Defaults (Continued)
Table B-8. System Configuration Defaults
Table B-7. SNMP Configuration Defaults
Set Command
Authority
Syntax
Keywords
Page
Set Config Command
Authority Syntax
Keywords
Table B-9. Set Config Port Parameters (Continued)
Table B-9. Set Config Port Parameters (Continued)
Page
Page
Table B-10. Set Config Switch Parameters (Continued)
Page
Examples
Table B-12. Set Config Zoning Parameters
59042-07 A B-45
The following is an example of the Set Config Switch command:
B-46 59042-07 A
The following is an example of the Set Config Threshold command:
59042-07 A B-47
The following is an example of the Set Config Zoning command.
Set Log Command
Syntax
Keywords
Page
Notes
Set Port Command
Authority Syntax
Keywords
Page
Set Setup Command
Syntax
Keywords
Page
Table B-14. System Configuration Settings (Continued)
Set Setup Command
B-56 59042-07 A
Examples
Set Setup Command
59042-07 A B-57
The following is an example of the Set Setup System command:
Show Command
Syntax
Keywords
Page
Page
Table B-15. Show Port Parameters (Continued)
Page
Page
Table B-16. Switch Operational Parameters (Continued)
59042-07 A B-65
Examples
The following is an example of the Show Domains command:
The following is an example of the Show Fabric command:
B-66 59042-07 A
The following is an example of the Show FDMI command:
The following is an example of the Show FDMI WWN command:
59042-07 A B-67
The following is an example of the Show NS (local domain) command:
The following is an example of the Show NS [domain_ID] command:
The following is an example of the Show NS [port_ID] command:
B-68 59042-07 A
The following is an example of the Show Interface command:
59042-07 A B-69
The following is an example of the Show Port command:
B-70 59042-07 A
The following is an example of the Show Switch command:
The following is an example of the Show Topology command:
59042-07 A B-71
The following is an example of the Show Topology command for port 1:
B-72 59042-07 A
The following is an example of the Show Version command:
Show Config Command
Syntax
Keywords
Examples
Show Config Command
The following is an example of the Show Config Switch command:
The following is an example of the Show Config Threshold command:
Show Config Command
59042-07 A B-75
The following is an example of the Show Config Zoning command:
Show Log Command
Syntax
Keywords
Page
Show Log Command
B-78 59042-07 A
Examples
The following is an example of the Show Log Level command:
The following is an example of the Show Log Options command:
The following is an example of the Show Log command:
Show Perf Command
Syntax
Keywords
Show Perf Command
B-80 59042-07 A
Examples
The following is an example of the Show Perf Byte command:
Show Setup Command
Syntax
Keywords
Examples
Show Setup Command
The following is an example of the Show Setup Snmp command:
Show Setup Command
59042-07 A B-83
The following is an example of the Show Setup System command:
Shutdown Command
Test Command
Syntax
Keywords
Examples
Page
Page
Uptime Command
User Command
Authority
Syntax
Keywords
Notes
Examples
The following is an example of the User Add command:
The following is an example of the User Edit command:
The following is an example of the User Delete command:
The following is an example of the User List command:
Whoami Command
Zone Command
Authority
Syntax
Keywords
Page
Zone Command
59042-07 A B-95
Examples
The following is an example of the Zone Members command:
Page
Zoneset Command
Authority
Syntax
Keywords
Notes
Examples
Zoning Command
Authority Syntax
Keywords
Page
Zoning Command
59042-07 A B-101
Examples
The following is an example of the Zoning Limits command:
Zoning Command
B-102 59042-07 A
The following is an example of the Zoning List command:
Page
Page
Glossary
Page
Page
Page
Page
Page
Index
Numerics
A
B
C
D
E
F
G
H
I
L
M
N
O
P
account
Q
R
S
T
U
V
W
Z