5 – Diagnostics/Troubleshooting

 

 

POST Diagnostics

 

 

 

 

g.Open an admin session to acquire the necessary authority.

SANbox2 $>admin start

h.Restore the configuration file. When the restore is complete, the switch will reset.

SANbox2 (admin) $>config restore

5.1.2

Logged-In LED Indications

Port diagnostics are indicated by the Logged-In LED for each port as shown in Figure 5-1.

Logged-In LED

Figure 5-1. Logged-In LED

The Logged-In LED has three indications:

„Continuous illumination: A device is logged in to the port.

„Flashing once per second: A device is logging in to the port.

„Flashing twice per second: The port is down, offline, or an error has occurred.

If a Logged-In LED shows an error indication, review the event browser for alarm messages regarding the affected port. You can also inspect the event log using the Show Alarm command. Pertinent alarm messages will point to one or more of the following conditions:

„E_Port isolation

„Excessive port errors