Table 3 Required Disk LUN Labels
Chapter 1 Installing StorNext File System and Storage Manager Getting Ready to Install
of the operating system running on the MDC as well as the operating system running on all connected clients. Disk LUNs can have one of three labels: VTOC, EFI, or sVTOC (short VTOC).
Required disk LUN label settings based on operating system and LUN size are presented in Table 3. Before installing StorNext, decide what label type will be used, and then install any required operating system patches or updates (for both MDC and client) as indicated in the notes for Table 3.
Note: After labeling a disk LUN, you must reboot systems running Solaris before they can access the disk LUN.
Operating | Label for | Label for | Label for |
System | LUNs < 1 TB | LUNs | LUNs > 2 TB |
|
|
|
|
Windows XPa | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
Windows 2003 | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
Server |
|
|
|
|
|
|
|
Linux 2.6 | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
Kernel |
|
|
|
|
|
|
|
Linux 2.4 | VTOC, EFI | VTOC, EFI | Not supported |
Kernel |
|
|
|
|
|
|
|
Solaris 9b | VTOC, EFI | EFI | Not supported |
Solaris 10c | VTOC, EFI | EFI | EFI |
VTOC, EFI | VTOC, EFI | EFI, sVTOC | |
IBM AIXd | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
SGI IRIX | VTOC | VTOC | Not supported |
|
|
|
|
Apple Xsan 1.3 | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
(MacOS X 10.4 |
|
|
|
Tiger) |
|
|
|
|
|
|
|
Apple Xsan 1.3 | VTOC, EFI | VTOC, EFI | EFI, sVTOC |
(MacOS X 10.3 |
|
|
|
Panther)a |
|
|
|
StorNext 3.1.3 Installation Guide | 6 |