Table 12 Distributed LAN Server Parameters
| Chapter 4 Configuring StorNext |
| Configuring a Distributed LAN Client Server |
|
|
Field / Button | Description |
|
|
tcp_window_size_kb | The TCP window size (in KB) used by the |
| distributed LAN server. (Default: 64) |
|
|
transfer_buffer_size_kb | The transfer buffer size (in KB) used by the |
| distributed LAN server. A larger buffer may |
| increase performance for larger files. |
| (Default: 256) |
|
|
transfer_buffer_count | The number of transfer buffers used by the |
| distributed LAN server. This parameter is |
| used only by Windows servers and clients. |
| Linux servers pass the value of this |
| parameter to Windows clients. (Default: 16) |
|
|
server_buffer_count | The number of I/O buffers allocated for |
| each network interface on the distributed |
| LAN server. This parameter is used only by |
| Linux servers. (Default: 8) |
|
|
daemon_threads | The maximum number of daemon threads |
| used by the distributed LAN server. |
| (Default: 8) |
|
|
6When you are done making edits, type :x to save and close the configuration file.
The configuration is saved in the file dpserver in the /user/cvfs/config/ directory.
Note: To edit this file at a later date, you can run the sndpscfg utility again or edit the dpserver file directly.
7Start the StorNext client. At the command prompt, type:
/etc/init.d/cvfs start
StorNext 3.1.3 Installation Guide | 70 |