Effects List

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17: Digital Chorus

 

Parameter

 

 

Value

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Balance

 

 

DRY100:0WET–

Volume balance between the di-

 

 

This is a stereo chorus or flanger. Equalizers are provided

 

 

 

 

DRY0:100WET

rect sound (DRY) and the delay

 

 

 

 

 

 

 

 

before (Pre) and after (Post) the chorus (or flanger).

 

 

 

 

 

 

 

 

sound (WET)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delay Pan Type

 

 

 

 

 

 

 

 

 

Parameter

Value

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

CHORUS,

Selects either chorus or flanger.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLANGER

 

Values

 

Dly 1

 

Dly 2

 

Dly 3

 

Dly 4

 

Dly 5

 

 

 

 

 

 

 

 

 

 

 

Rate

0.05–10.0 Hz,

Sets the cycle for the chorus or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

L63

 

 

L32

 

0

 

32R

 

63R

 

 

 

 

 

 

 

 

 

 

note

flanger sound undulations.

2

 

L63

 

 

32R

 

L32

 

63R

 

0

 

 

 

 

 

 

 

 

 

 

 

Depth

0–127

Adjusts the depth of modulation

3

 

L63

 

 

63R

 

L32

 

32R

 

0

 

 

 

 

 

 

 

 

 

 

 

 

for the chorus or flanger.

4

 

32R

 

 

L32

 

L63

 

0

 

63R

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

0–180 deg

Specifies the spaciousness of the

5

 

63R

 

 

0

 

L63

 

L32

 

32R

 

 

 

 

chorus or flanger sound.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre Low Freq

50–4000 Hz

Frequency of the low range (Pre)

6

 

L32

 

 

32R

 

L63

 

63R

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre Low Gain

-15– +15 dB

Gain of the low range (Pre)

7

 

0

 

 

 

63R

 

L63

 

32R

 

L32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre Hi Freq

2000–20000 Hz

Frequency of the high range (Pre)

8

 

0

 

 

 

63R

 

L32

 

32R

 

L63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre Hi Gain

-15– +15 dB

Gain of the high range (Pre)

9

 

0

 

 

 

32R

 

L32

 

63R

 

L63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre Dly Time

0–50.0 ms

Adjusts the delay time from the di-

10

 

63R

 

 

32R

 

0

 

L32

 

L63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rect sound until the chorus or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16: Analog DelayChorus

 

 

 

 

 

 

 

flanger sound is heard.

 

 

 

 

 

Feedback

-98– +98 %

Adjusts the proportion of the cho-

This effect reproduces the sound of the BOSS CE-1 Chorus

 

 

 

rus or flanger sound that is fed

 

 

 

back into the effect. Negative (-)

Ensemble. To reproduce the sound of the unit at the time, a

 

 

 

settings will invert the phase.

monaural analog-type delay is first inserted in series.

 

 

 

Xover Low-

50–4000 Hz

Attenuates the effect in the range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Freq

 

below the specified frequency.

Parameter

 

 

Value

 

Description

 

 

 

 

 

Xover Low

-36–0 dB

Specifies how greatly the low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dly Sw

 

 

OFF, ON

Turns the delay on/off.

 

 

 

Gain

 

range will be attenuated.

Dly Repeat

 

 

0–127

 

Corresponds to the delay time in a de-

 

 

 

 

 

 

 

 

 

 

Xover HiFreq

2000–20000 Hz

Attenuates the effect in the range

Rate

 

 

 

 

 

lay effects.

 

 

 

 

 

 

 

above the specified frequency.

Dly Intensity

0–127

 

Corresponds to the feedback setting in

 

 

 

 

 

 

 

 

Xover Hi

-36–0 dB

Specifies how greatly the high

 

 

 

 

 

 

 

a delay effects.

 

 

 

 

 

Gain

 

range will be attenuated.

Dly Level

 

 

0–127

 

Sets the volume of the delay sound.

 

 

 

 

 

 

 

 

 

 

Modulation

0–127

Volume of the chorus or flanger

Chorus Sw

 

 

OFF, ON

Turns chorus or vibrato on/off.

 

 

Level

 

sound.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ps Low Freq

50–4000 Hz

Frequency of the low range (Post)

Chorus Mode

CHORUS,

Switches the sound between chorus

 

 

 

 

 

VIBRATO

and vibrato modes.

 

 

 

Ps Low Gain

-15– +15 dB

Gain of the low range (Post)

Chorus Inten-

0–127

 

When Chorus Mode is CHORUS, this

 

 

 

 

 

 

 

 

Ps Hi Freq

2000–20000 Hz

Frequency of the high range (Post)

sity

 

 

 

 

 

sets the pitch vibrato speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ps Hi Gain

-15– +15 dB

Gain of the high range (Post)

Vibrato

 

 

0–127

 

When Chorus Mode is VIBRATO, this

 

 

 

 

 

 

 

 

 

 

Depth

 

 

 

 

 

sets the pitch vibrato depth.

 

 

 

 

 

 

Vibrato Rate

0–127

 

When Chorus Mode is VIBRATO, this

 

 

 

 

 

 

 

 

 

 

 

 

sets the pitch vibrato speed.

 

 

 

 

 

 

Chorus Out

 

 

MONO,

Switches the output format (mono/

 

 

 

 

 

Mode

 

 

ST-1, ST-2

stereo).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONO: Output is monaural.

 

 

 

 

 

 

 

 

 

 

 

 

ST-1: Chorus sound of the pitch vibra-

 

 

 

 

 

 

 

 

 

 

 

 

tion which phase is inverted between

 

 

 

 

 

 

 

 

 

 

 

 

left and right is mixed with the source

 

 

 

 

 

 

 

 

 

 

 

 

sound. This is a broader chorus, with

 

 

 

 

 

 

 

 

 

 

 

 

a weaker feeling of placement.

 

 

 

 

 

 

 

 

 

 

 

 

ST-2: The left output contains the

 

 

 

 

 

 

 

 

 

 

 

 

source sound, and the right side has

 

 

 

 

 

 

 

 

 

 

 

 

the wavering chorus sound.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

Page 50
Image 50
Roland VC-2 owner manual Digital Chorus, Analog Delay→Chorus, Delay Pan Type