Unit 5: Printer Configuration

PRINTER CONFIGURATION

The keys of the operator panel and dip switches are used either singularly or in conjuction to perform configuration activities. The dip switch complex is accessible from the right housing cover.

Refer to the Control Features chapter of the Introduction Unit for identification of specific interface features.

FACTORY DEFAULTS

DSW1

 

DSW2

 

 

 

DSW3

 

 

DSW4

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

OFF

 

 

 

OFF

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232C QUICK REFERENCE TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

DIP SWITCHES

HEAD

PRINT KEY

FEED KEY

 

 

 

 

 

 

 

 

 

 

 

 

Standard Start-Up

OFF

 

OFF

OFF

 

OFF

Closed

OFF

OFF

 

 

 

 

 

 

 

 

 

 

User Test Print

 

 

 

 

 

 

Closed

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

Default Reset

 

 

 

 

 

 

Opened

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

Hex Dump

OFF

 

OFF

ON

 

ON

Closed

OFF

OFF

 

 

 

 

 

 

 

 

 

 

Font Download

OFF

 

OFF

OFF

 

ON

Closed

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

Dispense Auto Print

 

 

 

 

 

 

Opened

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

Dispense Manual Print

 

 

 

 

 

 

Opened

OFF

OFF

 

 

 

 

 

 

 

 

 

 

Program Download

OFF

 

OFF

ON

 

OFF

Closed

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

Factory Clear (w/o counter)

 

 

 

 

 

 

Opened

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

Head Check

OFF

 

ON

OFF

 

ON

Opened

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

Cancel Head Check

 

 

 

 

 

 

Opened

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

Factory Clear (w’counter)

OFF

 

ON

ON

 

OFF

Opened

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IRDA QUICK REFERENCE TABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

DIP SWITCHES

HEAD

PRINT KEY

FEED KEY

 

 

 

 

 

 

 

 

 

 

 

 

Standard Start-Up

ON

 

OFF

OFF

 

OFF

Closed

OFF

OFF

 

 

 

 

 

 

 

 

 

 

User Test Print

 

 

 

 

 

 

Closed

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

Hex Dump

ON

 

OFF

ON

 

ON

Closed

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

Head Check

ON

 

OFF

OFF

 

ON

Opened

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

Cancel Head Check

 

 

 

 

 

 

Opened

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

Factory Clear (w/counter)

ON

 

OFF

ON

 

OFF

Opened

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

Online Command (MB200)

ON

 

ON

ON

 

ON

Opened

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

Online Command (SBPL)

 

 

 

 

 

 

Opened

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

SATO MB2i Service Manual