Communication

Notes:

The communication protocol is automatically detected by the SITRANS LU01 and shown via LED on the motherboard.

Ground shield at one end only.

Serial

RS-232

RS-485

 

 

 

 

 

 

 

 

 

 

 

 

Installation

to customer device,

to customer device,

RS-232 port

RS-485 port

15 m (50ft) max

1200 m (4,000 ft) max

SmartLinx

Refer to the appropriate SmartLinx manual for installation and wiring.

Level System Synchronization

Avoid mounting the SITRANS LU01 near another ultrasonic level monitor. Likewise, when more than one monitor is installed within a single plant/facility, ensure the transducer cables of each system are run in separate grounded metal conduits. If this system separation is impractical, or if measurement difficulties are encountered, system synchronization may be required.

Synchronize the SITRANS LU01 with another SITRANS LU01

1.Mount the level monitors together in one cabinet.

2.Ensure the level monitors share a common power (mains) supply, and ground (earth).

3.Interconnect the SYNC terminals of the level monitors to be synchronized.

Note: To synchronize the SITRANS LU01 with other Siemens Milltronics ultrasonic level monitors, contact Siemens Milltronics or your local distributor.