Siemens V4.0 manual Interval Regdword 1 to, MaxFilesInDirectory Regdword 0 to infinity

Models: V4.0

1 365
Download 365 pages 46.33 Kb
Page 313
Image 313

Advanced Server Registry

Replicator Service Entries

ImportPath

REG_SZ or REG_EXPAND_SZ Pathname

Specifies the path on the import server to receive replicas from the export servers. This value is ignored if the value of the Replicate key is 1 (Export).

Default: C:\var\opt\lanman\shares\asu\repl\import

Interval REG_DWORD 1 to 60

Specifies how often in minutes an export server checks the replicated directories for changes. Used in conjunction with the Pulse key. Ignored on import servers.

Default: 5

MaxFilesInDirectory REG_DWORD 0 to infinity

Specifies the maximum number of files in an import directory that can be replicated.

Default: 2000

Pulse REG_DWORD 1 to 10

Specifies in minutes how often the export server repeats sending the last update notice. These repeat notices are sent even when no changes have occurred, so that import servers that missed the original update notice can receive the notice. The server waits the equivalent of (Pulse * Interval) minutes before sending each repeat notice.

Default: 3

Random REG_DWORD 1 to 120

Specifies the maximum time in seconds that the import servers can wait before requesting an update. An import server uses the export server’s value of Random to generate a random number of seconds (from 0 to the value of Random). The import server waits this long after receiving an update notice before requesting the replica from the export server. This prevents the export server from being overloaded by simulta- neous update requests.

Default: 60

Replicate REG_DWORD 1, 2, or 3

Specifies the Replicator action, according to the following:

1 = Export — the server maintains a master tree to be replicated.

2 = Import — the server receives update notices from the export server.

3 = Both — the server is to export and import directories or files.

Default: Varies with role of server