Lanman.ini File

Parameters

 

 

 

 

 

[lmxserver] Section Parameters

 

 

 

 

 

Parameter

 

Description, Values, and Default Setting

 

 

 

 

 

lptmpdir

 

The location of the spooling directory for temporary

 

 

 

files used by the UNIX system’s LP subsystem.

 

 

 

Default: /var/spool/lp/tmp/uname where uname is the

 

 

 

server’s UNIX system name.

 

 

 

 

 

mapaclblob

 

Configures whether to use memory-mapped file opera-

 

 

 

tions when accessing the Advanced Server Access

 

 

 

Control List database.

 

 

 

Values: yes, no; default: yes

 

 

 

 

 

mapchangelogblob

 

Configures whether to use memory-mapped file opera-

 

 

 

tions when accessing the Advanced Server Change

 

 

 

Log database.

 

 

 

Values: yes, no; default: no

 

 

 

 

 

maplsablob

 

Configures whether to use memory-mapped file opera-

 

 

 

tions when accessing the Advanced Server Local

 

 

 

Security Authority database.

 

 

 

Values: yes, no; default: no

 

 

 

 

 

mapregistryblob

 

Configures whether to use memory-mapped file opera-

 

 

 

tions when accessing the Advanced Server Registry

 

 

 

database.

 

 

 

Values: yes, no; default: no

 

 

 

 

 

mapsamblob

 

Configures whether to use memory-mapped file opera-

 

 

 

tions when accessing the Advanced Server Security

 

 

 

Accounts Manager database.

 

 

 

Values: yes, no; default: no

 

 

 

 

 

maxfilesize

 

The maximum file size, in KBytes, that the UNIX

 

 

 

system redirector will allow a “local UNIX user” to

 

 

 

create on a local system.

 

 

 

Values: 100 - unlimited; default: 100000

 

 

 

 

 

maxspoolfds

 

This parameter is only evaluated if the lmxspooler

 

 

 

parameter is set to “SPOOLV4”. It specifies the number

 

 

 

of file descriptors in the lower range that are to be

 

 

 

reserved for calls to Spool/Xprint. The parameter is set

 

 

 

optimally for the current Spool/Xprint versions and may

 

 

 

only be changed by Technical Support.

 

 

 

Default: 4

 

 

 

 

 

 

 