Simrad AP26, AP27 manual Service Menu, Recall Autotuned?

Models: AP26 AP27

1 152
Download 152 pages 5.3 Kb
Page 109
Image 109

Maintenance

New course

Correct setting of counter rudder, ideal response

Autotrim standard value is 40 sec. which should work well on most boats.

Rudder Limit should be kept at 20 degrees unless there is a need for more rudder when performing dockside manoeuvres.

Recall Autotuned?

To recall the parameter values that were achieved during the Automatic tuning procedure, rotate the course knob clockwise. When parameter values are recalled, Confirmed is displayed.

Exit the Parameter menu by pressing STBD button to proceed to the Service menu, or press STBY to return to normal autopilot operation.

4.9Service Menu

Select STANDBY mode and then enter the Installation Menu by pressing and holding the NAV/WIND/SETUP button for 5 seconds. Select "Service by pressing the STBD button and confirm by rotating the course knob clockwise.

System data and SimNet/NMEA data are test functions to analyze data processed by the autopilot.

To exit the menu, press any mode key (STBY, AUTO or NAV).

20221586B