Simrad AP26 and AP27 Autopilots

Display readout

Probable fault

Recommended action

Com. failure with

Faulty Autopilot

1.

Check Robnet2 connectors and

ACXX

Computer or poor

 

cable.

 

Robnet2 cable

2.

Replace Autopilot Computer Main

 

connections from

 

 

PCB.

 

the same.

 

 

 

 

Low supply

Mains voltage less

1.

Verify in the System Data Menu

voltage

than 9 Volts

2.

Switch autopilot off, charge

 

 

 

 

 

batteries

 

 

3.

Check/repair battery charger

High supply

AC20/AC40 Mains

1.

Verify in the System Data Menu

voltage

exceeds 44 V

2.

Switch the autopilot off

 

AC10 Mains

 

3.

Check / repair battery charger

 

exceeds 29 V