8.4Autopilot Computers

Dimensions:

See Figure 8-3and Figure 8-4

Weight:

 

AC10/AC20

1,3 kg (2,9 lbs.)

AC40

2,8 kg (6,2 lbs)

Supply voltage:

 

AC10

10-28V DC

AC20/AC40

10-40V DC

Reverse voltage protection

Yes (not AC40)

Power consumption:

5 Watt (electronics)

Motor / solenoid drive:

 

AC10:

6 A continuous, 12 A for 5 sec.

AC20:

10 A continuous, 20 A for 5 sec.

AC40:

20 A continuous, 40 A for 5 sec.

Heading Sensor input:

Composite pulse width modulated

Rudder feedback input:

Frequency signal, 3400 Hz., 20 Hz/deg.

Rudder feedback units:

RF300, LF3000

NMEA input/output ports:

AC10:1 (one)

 

AC20, AC40: 2 (two)

External Alarm:

Open collector

Temperature range:

 

Operation:

0 to +55 °C (+32 to +130 °F)

Storage:

–30 to +80 °C (–22 to +176 °F)

Mounting:

Bulkhead mount

Material:

Anodized aluminium and black ABS cover

130