Technical specifications

8.11IS15 Rudder

Dimensions:

See Figure 8-11

Weight:

225 grams

Environmental Protection:

IP56 from front, IP44 from rear

Power requirement:

12/24 VDC, 70 mA (100 mA max with max

 

lighting)

Safe distance to compass:

0.15 m (0.5 ft.)

Temperature: Operating:

–0 to +55°C (+32 to +130°F)

Storage:

–30 to +80°C (–22 to +176°F)

Scale:

Full deflection adjustable for any h.o. angle

 

between ±20° and ±45°. Divisions: Marking per

 

each 1/8 of full deflection. Accuracy: ±2° of full

 

scale deflection.

Heading Display (Digital):

0 to 359°

Heading Resolution:

Heading reference:

True or Magnetic North

Heading Lock:

Course and direction to steer on digital display

Course to Steer:

Settable on digital display

Display Backlighting:

Green color with seven levels plus Off

Display Backlighting Control:...

Two independent lighting banks or individual

 

settings (bank 0)

Inputs: Rudder Angle:

2-wire p.w.m.

 

NMEA 0183, RSA

 

Roblink (IS15 system)

Compass heading:

NMEA 0183, HDG, HDM, HDT

Outputs: Rudder Angle:

NMEA 0183, RSA, 5 Hz*

Compass heading:

NMEA 0183, HDG

Other:

NMEA 0183 sentences according to IS15

 

NMEA in/out table.