Simrad AP26 and AP27 Autopilots

3.11Control unit installation

Avoid mounting the control unit(s) where it is easily exposed to sunlight, as this will shorten the lifetime of the display. If this is not possible, make sure the units are always covered with the white protection cover when not used.

Caution ! Do not install the control unit where moisture at the rear can be present. It could cause damage by entering the breathing hole or by coming into contact with the electrical connectors.

Panel mounting of AP26

This side towards control unit

The mounting surface must be flat and even to within 0.5 mm.

Drill the 4 mounting holes and make a panel cut-out according to supplied template.

Place one of the three supplied gaskets between the panel and the unit with the interlocking feature correctly orientated (see figure).

Use the supplied screws to fasten the control unit to the panel. Do not over-tighten the mounting screws!

Apply the front panel corners.

Connect the Robnet2 cable(s) to the control unit connector(s)

Alternative panel mounting of AP26

This side towards control unit

This way of mounting is simpler, but will lift the unit from the panel surface. When installed adjacent to Simrad equipment there will be a difference in height between the autopilot and the other equipment.

Use the template and drill hole(s) only for the connectors.

Place all three gaskets between panel and unit with the interlocking feature correctly orientated (see figure).

Follow above panel mounting instructions but use the supplied 32 mm screws to fasten the control unit to the panel

Do not over-tighten the mounting screws!