Maintenance

4.5Interface Settings

Sets the format of the clock/data output for radars connected to the Autopilot Computer.

Step to the Interface part of the Installation Menu.

Turn the course knob clockwise to access the Interface Setup items.

Use the course knob to select the connected type of radar.

Note ! This setting is not available in the AC10 Autopilot Computer.

4.6Display units

Select Display units by pressing STBD button and confirm by rotating the course knob clock- wise. This screen gives access to the display unit set-up of the Wind Speed, Sea temperature and Depth. The setup is local to each control unit.

Use the STBD button to select an item and the course knob to select the unit.

Available units are:

Wind Speed: Knots (kt) or meter/second (m/s)

Sea temperature:

Fahrenheit (°F) or Celsius (°C) Depth: Meter (m) or feet (ft)

Exit the Display units menu by pressing STBD button to proceed to the Sea trial menu, or press STBY to return to normal autopilot operation.