Note

The default IP address for LAN port 1 is follows;LAN connector 1: 192.168.0.1LAN connector 2: 192.168.1.1 (only the NSR-100/50)LAN connector 3: 192.168.2.1(only the NSR-100/50)

If you want to change the default IP address, refer to the “User’s Guide” (PDF) on the supplied “NSR Series Manual, Tool & Source Codes CD”.

Connecting an Uninterruptible Power Supply1 Connect the uninterruptible power source to the power outlet.2 Connect the NSR to the UPS with the supplied power cord.

3 Connect the NSR to the UPS with the dedicated serial cable to the serial connector on the rear of the NSR.

Connecting a Network Camera

Use a network cable to connect LAN connector 1 to a network switch, and then connect the desired network camera to the network switch with another network cable.

Network switch

Network Camera

Connecting Other DevicesUsing a CompactFlash Card (Only the NSR-100/50)

Insert your CompactFlash card in the direction illustrated. Make sure that you insert your card with the label side facing up and in the direction of the arrow.

POWER

LAN 1 2 3

HDD 1 2 3 4

STATUS 1 2 3 4

ERROR

REC

When ejecting a CompactFlash card, press the eject button on the left of the card slot.

Caution

Be careful when ejecting a CompactFlash card, because it may be expelled from the drive energetically.

Connecting Remote Client

If a remote client is required, the supplied RealShot Manager Controller software can be used. RealShot Manager Controller runs on Windows computers. For details on system requirements, refer to the release notes accompanying the RealShot Manager Controller install archive. Also, make sure to use the RealShot Manager supplied with the NSR.

1 Use a network cable to connect LAN connector to a network switch.When using the NSR-100/50, connect to LAN connector 2 on the unit.

2 Connect the network cable to a computer when RealShot Manager Controller software is installed.

Network switch

(For the NSR-100/50)

RealShot Manager

Controller software

Windows PC

Notes

For details on installation and other topics related to the RealShot Manager Controller software, refer to the supplied NSR Series Manual, Tool & Source Codes CD.

When using RealShot Manager as a remote controller for the NSR, select [Controller] during installation of RealShot Manager.

The default connection port for the RealShot Manager server function on the NSR unit is “8081”. The connection port can be changed from the NSR.

When using the NSR-100/50, use LAN connector 2 at the rear of the NSR even if connecting it to the user area of a network.

Installation 15