STATUS LEDWhen an error occurs, the STATUS and ERROR LED light or flash.

STATUS

 

1

 

2

 

3

 

4

 

ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The STATUS LED indicates the following error situations.

Error codes displayed during boot stage (The ERROR LED blinks when an error occurs during boot.)

Error

STATUS

ERROR

Possible Cause

code

LED

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

Blinking

Voltage power supply

 

1

 

2

 

3

 

4

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

Blinking

CPU fan failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

Blinking

Defective memory module

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

Blinking

CMOS battery failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video random access

5

 

1

 

2

 

3

 

4

 

Blinking

memory (RAM) or

 

 

 

 

 

 

 

 

 

 

 

controller failure

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

Blinking

Hard disk controller failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

Blinking

No bootable device found

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

Blinking

No bootable Operating

 

1

 

2

 

3

 

4

 

 

 

 

 

 

System found

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

Blinking

One or more hard disk

 

1

 

2

 

3

 

4

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

Blinking

RAID OS volume failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

Blinking

Failure to start the X11

 

1

 

2

 

3

 

4

 

 

 

 

 

 

server

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

Blinking

Failure to start the

 

1

 

2

 

3

 

4

 

 

 

 

 

 

application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

Blinking

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

Blinking

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

Blinking

RAID data volume failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Error codes displayed during operation stage (The ERROR LED lights when an error occurs during operation.)

Error

STATUS

ERROR

Possible Cause

code

LED

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

On

Critical temperature

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

On

CPU fan failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

On

Power supply fan failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

On

Voltage power supply

 

1

 

2

 

3

 

4

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

On

Hard disk drive fan 1 failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

On

Hard disk drive fan 2 failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

On

Hard disk drive is damaged.

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

On

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

On

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

On

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

On

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

On

Application functioning

 

1

 

2

 

3

 

4

 

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

On

Reserved for future use

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

On

RAID data volume failure

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

On

Resync operation in RAID

 

1

 

2

 

3

 

4

 

 

 

 

 

 

data volume*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*A degradation in system performance will occur when a read error occurs while the resync operation is in progress.