flashupdate Command Platform Shell—Examples

Note In the following examples, since the output is very long, only the command you type is listed in the code box.

Note Theflashupdate all, flashupdate rtos, and flashupdate scapp commands cause the system controller to reboot once.

To update the active System Controller board and the system controller real time operating system (rtos), perform this procedure from the platform console and watch the console output. This command reboots the system controller. Type:

CODE EXAMPLE 3-19flashupdate Example Updating the Active System Controller Board and the System Controller Real Time Operating System

schostname:SC> flashupdate -f ftp://host/path scapp rtos

To upgrade the firmware on a replacement CPU/Memory board, sb4 (destination_board), which is a replacement CPU/Memory board for CPU/Memory board, sb0 (source_board). Type:

CODE EXAMPLE 3-20flashupdate Example Updating Replacement CPU/Memory Board sb4

schostname:SC> flashupdate -c sb0 sb4

42 Sun Fire 6800/4810/4800/3800 System Controller Command Reference Manual • October 2001