Description
Powers on a component or a list of components You must specify component_name(s).
You can power on any component that is not already powered on if there is sufficient power to support the component when it is powered on. From the domain, only components that are assigned to the domain can be powered on. To power on a component, the power grid power must also be on.
Fan trays are automatically powered on when a power supply is powered on. Fan trays obtain power from the power grid(s).
The System Controller boards obtain their power from a secondary power output on the power supplies. The System Controller boards power on automatically when the system is supplied with power. For example, the System Controller boards will power on automatically on a Sun Fire 6800 system if the power cords are connected, the system has power, and the circuit breaker(s) are on. The System Controller board will automatically power on the Sun Fire 4810/4800/3800 systems if the power cords are connected to the power source, the system has power, and the power supply switches are turned on (Sun Fire 3800 system only).
The fan trays power on automatically if any power supply is on.
See Also
poweroff, setkeyswitch, showboards
Examples
To power on CPU/Memory board, sb2 from the platform shell (CODE EXAMPLE
CODE EXAMPLE 3-29 poweron Example Powering On sb2
schostname:SC> poweron sb2
Chapter 3 System Controller Alphabetical Command Reference 53