poweron

Powers on components.

Scope

platform shell, domain shell

Syntax for the Platform Shell

poweron allgrid#component_name [component_name . . . ]

poweron -h

Syntax for the Domain Shell

poweron allcomponent_name [component_name . . . ]

poweron -h

Options/Parameters

-hdisplays help for this command.

Platform shell component_name(s):

all is all power supplies and boards.

Power grid (grid0, grid1). The Sun Fire 6800 system has two power grids: grid0 and grid1. Grid 1 controls power supplies ps3, ps4, and ps5. All of the other mid- range systems have one power grid, grid0. This grid controls power supplies ps0, ps1, and ps2.

Power supply (ps0 - ps5)

CPU/Memory board (sb0 - sb5)

I/O assembly (ib6 - ib9)

Repeater board (rp0 - rp3)

Fan tray (ft0 - ft3)

Domain shell component_names:

all powers on all CPU/Memory boards and I/O assemblies in the domain

CPU/Memory board (sb0 - sb5)

I/O assembly (ib6 - ib9)

The specified board must be in the current domain.

52 Sun Fire 6800/4810/4800/3800 System Controller Command Reference Manual • October 2001

Page 68
Image 68
Sun Microsystems 6800/4810/4800/3800 manual Poweron