Sun Microsystems 6800/4810/4800/3800 manual Ppart shows a specific part Table

Models: 6800/4810/4800/3800

1 138
Download 138 pages 63 Kb
Page 116
Image 116

-ppart shows a specific part (TABLE 3-13):

TABLE 3-13

Parts for showenvironment -p part

 

 

Report

Description

 

 

currents

Displays currents (power supplies only)

fans

Displays fan states.

faults

Displays values that are suspected to be invalid.

temps

Displays temperatures only.

voltage

Displays voltages only.

 

 

-tprints header titles.

-uupdates data now. Polls all sensors for new values.

-vis verbose mode. This is the equivalent of the options -land -w.

-wshows warning thresholds.

Description

Displays the current environmental status, temperatures, currents, voltages, and fan status for the system (platform shell) or the current domain (domain shell). In a domain shell, the domain can only display boards that have been assigned to the domain, such as CPU/Memory boards and I/O assemblies. The board(s) must be powered on. Boards that are not powered on are not monitored and have no environmental data.

This command displays the minimum and maximum values. If these values are exceeded, the component (and the domain using the component) will be shut down. It also shows the warning levels when the system controllers warns you that you are approaching the limits.

TABLE 3-14describes the showenvironment output headers and values.

TABLE 3-14showenvironment Output Header Description

Header

Value

Description

 

 

 

Slot

 

Slot ID

Device

 

Device being monitored by the sensor.

Sensor

 

Component that measures the environmental

 

 

data of the device.

 

 

 

100 Sun Fire 6800/4810/4800/3800 System Controller Command Reference Manual • October 2001