TABLE
Current Setting | New Setting | Result |
|
|
|
standby | off | All boards will be powered off (set to low |
|
| all monitoring of the boards will stop). The domain is shut |
|
| down. |
standby | on | Similar to setting the virtual keyswitch from off to on except |
|
| that you do not have to wait for the system controller to turn |
|
| on the boards and prepare them. |
on | off | All boards will be powered off (set to low |
|
| all monitoring of the boards will stop). The domain is shut |
|
| down. |
on | standby | The domain becomes inactive. All of the boards remain |
|
| powered on. |
on | on | Keyswitch position not changed. |
on | diag | Similar to the setkeyswitch on command except the POST |
|
| verbose mode is set to on and the POST diagnostic level is set |
|
| to maximum. This change is setting has no effect on a running |
|
| domain. |
on | secure | break and reset are ignored. |
diag | off | All boards will be powered off (set to low |
|
| all monitoring of the boards will stop). The domain is shut |
|
| down. |
diag | standby | The domain becomes inactive. All of the boards remain |
|
| powered on. |
diag | on | Has no effect on a running domain. This operation only |
|
| changes the keyswitch position and does not perform any |
|
| other function since the domain is already running. |
diag | diag | Keyswitch position not changed. |
diag | secure | break and reset are ignored. |
secure | off | All boards will be powered off (set to low |
|
| all monitoring of the boards will stop). The domain is shut |
|
| down. |
secure | standby | The domain becomes inactive. All of the boards remain |
|
| powered on. The break and reset commands are no longer |
|
| ignored. |
secure | on | break and reset are not ignored. |
secure | diag | This change is setting has no effect on a running domain. |
secure | secure | Keyswitch position not changed. |
|
|
|