Manuals
/
Brands
/
Computer Equipment
/
Power Supply
/
TDK
/
Computer Equipment
/
Power Supply
TDK
750W HALF RACK technical manual
1
1
82
82
Download
82 pages, 1.9 Mb
TECHNICAL MANUAL FOR
GENESYS
TM
750W HALF RACK
Programmable DC Power Supplies
Document: 83-507-5002 Rev B
TDK-Lambda Americas Inc
.
405 Essex Road, Neptune, NJ 07753
Tel:
(732) 922-9300
Fax:
(732) 922-9334
Web: www.US.TDK-Lambda.com/HP
Contents
Main
GENESYS
750W HALF RACK
Programmable DC Power Supplies
TDK-Lambda Americas Inc.
Page
Page
GENESYS Manual Supplement
FOR UNITS EQUIPPED WITH IEMD OPTION. ALSO REFER TO MANUAL 83-030-200 IEMD.
Page
Page
Page
Page
83-000-016 Rev. F
WARRANTY
LIMITATION OF WARRANTY
WARRANTY SERVICE
DISCLAIMER
SAFETY INSTRUCTIONS
CAUTION
INSTALLATION CATEGORY
GROUNDING
FUSES
SAFETY INSTRUCTIONS
ENVIRONMENTAL CONDITIONS
SICHERHEITS-INSTALLATIONS ANWEISUNGEN
Page
6
CHAPTER 1 GENERAL INFORMATION
1.1 USER MANUAL CONTENT
1.2 INTRODUCTION
Page
8
1.3 ACCESSORIES
CHAPTER 2 SPECIFICATIONS
Page
Page
Page
13
3.1 GENERAL
3.2 PREPARATION FOR USE
3.3 INITIAL INSPECTIONS
14
3.4 RACK MOUNTING
15
3.5 LOCATION, MOUNTING AND COOLING
3.6 AC SOURCE REQUIREMENTS
3.7 AC INPUT POWER CONNECTION
16
3.8 TURN-ON CHECKOUT PROCEDURE
Page
18
3.9 CONNECTING THE LOAD
Page
Page
Page
Page
- -
+ +
- -
+ +
Page
25
WARNING OUTPUT TERMINAL GROUNDING
3.10 LOCAL AND REMOTE SENSING
WARNING
Page
27
CHAPTER 4 FRONT AND REAR PANEL CONTROLS AND CONNECTORS
4.1 INTRODUCTION
4.2 FRONT PANEL CONTROLS AND INDICATORS
Page
29
4.3 REAR PANEL CONNECTIONS AND CONTROLS
30
4.4 REAR PANEL SW1 SETUP SWITCH
Fig.4-3: SW1 setup DIP-switch
4.5 REAR PANEL J1 PROGRAMMING AND MONITORING CONNECTOR
Page
Page
34
CHAPTER 5 LOCAL OPERATION
5.1 INTRODUCTION
5.2 STANDARD OPERATION
35
5.3 OVER VOLTAGE PROTECTION (OVP)
36
5.4 UNDER VOLTAGE LIMIT (UVL)
5.5 FOLDBACK PROTECTION
5.6 OUTPUT ON/OFF CONTROL
5.7 OUTPUT SHUT-OFF (SO) CONTROL VIA REAR PANEL J1 CONNECTOR
37
5.8 ENABLE/DISABLE CONTROL VIA REAR PANEL J1 CONNECTOR
5.9 CV/CC SIGNAL
38
5.10 PS_OK SIGNAL
5.11 SAFE-START AND AUTO-RESTART MODES
5.12 OVER TEMPERATURE PROTECTON (OTP)
5.13 LAST SETTING MEMORY
39
5.14 SERIES OPERATION
Page
41
5.15 PARALLEL OPERATION
Page
Page
44
5.16 DAISY-CHAIN CONNECTION
5.17 FRONT PANEL LOCKING
Page
46
CHAPTER 6 REMOTE ANALOG PROGRAMMING
6.1 INTRODUCTION
6.2 LOCAL/REMOTE ANALOG INDICATION
6.3 LOCAL/REMOTE ANALOG INDICATION
47
6.4 REMOTE VOLTAGE PROGRAMMING OF OUTPUT VOLTAGE AND OUTPUT CURRENT LIMIT
48
6.5 RESISITIVE PROGRAMMING OF OUTPUT VOLTAGE AND CURRENT LIMIT
49
6.6 REMOTE MONITORING OF OUTPUT VOLTAGE AND CURRENT
50
CHAPTER 7 RS232 & RS485 REMOTE CONTROL
7.1 INTRODUCTION
7.2 CONFIGURATION
51
7.3 REAR PANEL RS232/RS485 CONNECTOR
52
7.4 MD MODE OPTION (Factory Installed)
8 PIN CONNECTOR
53
7.5 CONNECTING POWER SUPPLIES TO RS232 OR RS485 BUS
Select the desired interface RS232 or RS485 using rear panel setup switch SW1-6 (Section 4-4).
7.5.1 Single power supply 1.
DB-25 CONNECTOR 8 PIN CONNECTOR REMARKS
54
7.6 COMMUNICATION INTERFACE PROTOCOL
55
7.7 ERROR MESSAGES
7.8 COMMAND SET DESCRIPTION
Page
Page
58
7.9 GLOBAL OUTPUT COMMANDS
59
7.10 SINGLE BYTE COMMANDS
Page
Page
Page
63
7.11 STATUS, ERROR AND SRQ REGISTERS
Page
7.11.2 Conditional Registers (continued) Table 7-8: Fault Condition Register BIT Fault name
Fault symbol Bit Set condition Bit Reset condition
Table 7-9: Status Condition Register BIT Fault name
Page
Page
68
7.12 SERIAL COMMUNICATION TEST SET-UP
69
CHAPTER 8 ISOLATED ANALOG PROGRAMMING OPTION
8.1 INTRODUCTION
8.2 SPECIFICATIONS
70
8.3 ISOLATED PROGRAMMING & MONITORING CONNECTOR
71
8.4 SETUP AND OPERATING INSTRUCTIONS
72
CHAPTER 9 MAINTENANCE
9.1 INTRODUCTION
9.2 UNITS UNDER WARRANTY
9.3 PERIODIC MAINTENANCE
9.4 ADJUSTMENTS AND CALIBRATION
Page
74
9.7 FUSE RATING