CHAPTER 6 REMOTE ANALOG PROGRAMMING
6.1 INTRODUCTION
The rear panel connector J1 allows the user to program the power supply Output Voltage and Current with an analog device. J1 also provides monitoring signals for Output Voltage and Out- put Current. The programming range and monitoring signals range can be selected between 0- 5V or
CAUTION
COM
6.2 LOCAL/REMOTE ANALOG INDICATION
Contact 8 of J1
In Local mode, the Output Voltage and Output Current can be programmed via the front panel VOLTAGE and CURRENT encoders or via the RS232/RS485 port. In Remote Analog mode, the Output Voltage and current can be programmed by analog voltage or by programming resistors via J1 contacts 9 and 10 (refer to Sections 6.4 and 6.5). Refer to Table
Output Voltage/ | |||
Current setting | |||
|
| ||
Down (default) | No effect | Local | |
Up | “0” or Short | Remote | |
“1” or Open | Local | ||
|
Table
6.3 LOCAL/REMOTE ANALOG INDICATION
Contact 21 of J1 (Fig.
Mode | ||||
|
|
|
|
|
TTL “0” or short | Down | Down | Open | Local (FP) |
| Down | Up | 0i0.6V | Remote Ana- |
|
|
|
| log |
| Up | Down | 0i0.6V | Remote Ana- |
|
|
|
| log |
| Up | Up | 0i0.6V | Remote Ana- |
|
|
|
| log |
TTL “1” or open | Down or Up | Down or Up | Open | Local (FP) |
Table
46