83-507-5002 Rev. B

9
CHAPTER 2 SPECIFICATIONS
2.1 OUTPUT RATING
MODEL
GEN
6-100
8-90
12.5-60
20-38
30-25
40-19
60-12.5
80-9.5
100-7.5
150-5
300-2.5
600-1.3
1.Rated output voltage (*1)
V
6
8
12.5
20
30
40
60
80
100
150
300
600
2.Rated output current 750W (*2)
A
100
90
60
38
25
19
12.5
8.5
7.5
5
2.5
1.3
3.Rated output power 750W
W
600
720
750
760
750
760
750
760
750
750
750
780
MODEL
GEN
6-200
8-180
12.5-120
20-76
30-50
40-38
50-30
60-25
80-19
100-15
150-10
300-5
600-2.6
1.Rated output voltage (*1)
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
2.Rated Output Current 1500W (*2)
A
200
180
120
76
50
38
30
25
19
15
10
5
2.6
3.Rated output power 1500W
W
1200
1440
1500
1520
1500
1520
1500
1500
1520
1500
1500
1500
1560
2.2 INPUT CHARACTERISTICS
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Input voltage/freq. (*3)
2. Input current (at 100/200Vac)
A
3. Power Factor
4. 750W models Efficiency (*4)
%
76/78
77/80
81/84
82/85
82/85
83/87
83/87
83/87
83/87
83/87
83/87
83/87
83/87
5. 1500W models Efficiency (*4)
%
77/79
78/81
82/85
83/86
83/86
84/88
84/88
84/88
84/88
84/88
84/88
84/88
84/88
6. Inrush current at 100/200V
A
2.3 CONSTANT VOLTAGE MODE
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Max.Line regulation (*5)
2. Max.Load regulation (*6)
3. Ripple and noise (p-p,20MHz) (*10)
mV
60
60
60
60
60
60
60
60
80
80
100
150
300
4. Ripple r.m.s., 5Hz~1MHz (*10)
mV
8
8
8
8
8
8
8
8
8
8
10
25
60
5. Temperature coefficient
PPM/°C
100PPM/°C of rated output voltage, following 30 minutes warm up
6. Temperature drift
7. Rem. Sense compensation/wire
V
1
1
1
1
1.5
2
2
3
4
5
5
5
5
8. Up-prog. Response time 0~Vomax (*9)
mS
250
9. Down-prog. Response time: Full load
mS
10
250
No load
500
600
700
800
900
1000
1100
1100
1200
1500
2000
2500
4000
10. Transient response time
mS
11. Hold-up time
mS
2.4 CONSTANT CURRENT MODE
V
6
8
12.5
20
30
40
50
60
80
100
150
300
600
1. Max.line regulation (*5)
2. Max.load regulation (*7)
3. Ripple r.m.s. 5Hz~1MHz.750W (*8)
mA
200
180
120
76
63
48
38
29
23
18
13
8
1500W (*8)
mA
400
360
240
152
125
95
75
75
57
45
35
25
12
4. Temperature coefficient
PPM/°C
5. Temperature drift
2.5 ANALOG PROGRAMMING AND MONITORING
1.Vout voltage programming
2. Iout voltage programming
3. Vout resistor progrmming
4. Iout resistor programming
5. On/off control
6. Output current monitor
7. Output voltage monitor
8. Power supply OK signal
9. Parallel operation
10. Series operation
11. CV/CC inicator
12. Enable/Disable
13. Local/Remote analog control
14. Local/remote analog indicator
85~265Vac continuous, 47-63Hz, single phase.
10.5/5 for 750W model, 21/11 for 1500W models.
0.99@100/200Vac, rated output power.
Less than 25A for 750W models, 50A for 1500W models.
0.01% of rated output voltage +2mV
0.01% of rated output voltage +2mV
0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
80
150
50
80
150
Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current.
Output set-point: 10~100%.
Less than 1mS for models up to and including 100V; 2mS for models above 100V.
More than 20mS, 100Vac, rated output power.
0.01% of rated output voltage +2mA
0.02% of rated output current +5mA
100PPM/°C from rated output current, following 30 minutes warm-up.
0.05% of rated lout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: 1%
0~5V or 0~10V, user selectable. Accuracy: 1%
4~5V-OK, 0V-Fail, 500ohm series resistance.
Possible, up to 4 units in master/slave mode with single wire current balance connection.
Possible (with external diodes), up to 2 units.
CV: TTL high (4~5V), source current: 10mA, CC: TTL low (0-0.6V). Sink current: 10mA .
Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local.
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.