2.6 PROGRAMMING AND READBACK (RS232/485, Optional IEEE Interface)
1. | Vout programming accuracy |
| – |
| 0.05% + 0.05% of rated output voltage. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
2. | Iout programming accuracy (*13) |
| – |
| 0.1% of actual output current + 0.1% of rated output current (for Iout >0.4% of rated Iout to 100% of rated Iout). |
|
|
| |||||||||||||
|
|
|
|
| 0.1% of actual output current +0.4% of rated output current (for Iout <0.4% of rated Iout to 0.4% of rated Iout). |
|
|
| |||||||||||||
3. | Vout programming resolution. |
| – |
| 0.012% of full scale. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
4. | Iout programming resolution |
| – |
| 0.012% of full scale. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
5. | Vout readback accuracy |
| – |
| 0.1% + 0.1% of rated output voltage |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
6. | Iout readback accuracy (*13) |
| – |
| 0.1% + 0.3% of rated output current |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
7. | Vout readback resolution |
| – |
| 0.012% of full scale |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
8. | Iout readback resolution |
| – |
| 0.012% of full scale |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
2.7 PROTECTIVE FUNCTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| V |
| 6 | 8 | 12.5 |
| 20 |
| 30 | 40 | 50 | 60 |
| 80 |
| 100 | 150 | 300 | 600 | ||
1. | Foldback protection |
| Output shut |
|
|
|
|
|
|
|
|
| |||||||||
2. |
| Inverter |
|
|
|
|
|
|
|
|
|
| |||||||||
3. |
|
| V |
|
|
|
|
|
| ||||||||||||
4. | Output under voltage limit |
| Preset by | front panel | or communication port. Prevents adjusting Vout below limit. Raises the PS_OK signal in case |
|
|
|
| ||||||||||||
|
|
| output | voltage is below limit. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
5. | Over temperature protection |
| User selectable, latched or non latched. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
2.8 FRONT PANEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1. | Control functions |
| – |
| Vout/Iout manual adjust by separate encoders. (Coarse and fine adjustment) |
|
|
|
|
|
|
|
| ||||||||
|
|
| – |
| OVP/UVL manual adjust by Volt. Adjust encoder |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| – |
| Address selection by Voltage adjust encoder. No of addresses: 31 |
|
|
|
|
|
|
|
|
| |||||||
|
|
| – |
| Go to local control |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| – |
| Output on/off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| – |
| AC on/off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| – |
| Front panel lock |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| – |
| Foldback control |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| – |
| Serial or IEEE display at |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| – |
| Baud rate selection: 1200, 2400, 4800, 9600 and 19200 |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| – |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
2. | Display |
| – |
| Vout: | 4 digits, accuracy: 0.5% of rated voltage + 1 count |
|
|
|
|
|
|
|
|
| ||||||
|
|
| – |
| Iout: | 4 digits, accuracy: 0.5% of rated current + 1 count |
|
|
|
|
|
|
|
|
| ||||||
3. Indications |
| – |
| VOLTAGE, | CURRENT, ALARM FINE, PREVIEW, FOLDBACK, LOCAL, OUTPUT ON. |
|
|
|
|
|
| ||||||||||
2.9 ENVIRONMENTAL CONDITIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1. | Operating temperature |
| C |
| 0~50 C, 100% load. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
2. | Storage temperature |
| C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
3. | Operating humidity |
| % |
| 30~90% RH (no condensation). |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
4. | Storage humidity |
| % |
| 10~95% RH (no condensation). |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
5. | Altitude |
| – |
| Maximum 3000m, Derate output current by 2%/100m above 2000m. Alternatively, derate maximum ambient |
|
|
| |||||||||||||
|
|
|
|
| temperature by 1 degC/100m above 2000m. |
|
|
|
|
|
|
|
|
|
|
| |||||
2.10 MECHANICAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1. | Cooling |
| – |
| Forced air cooled by internal fans. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
2. | Weight |
| Kg |
| Less than 4.5Kg |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
3. | Dimensions (W x H x D) |
| mm |
| W: 214.0 H: 43.6 (57.0 Benchtop Version). D: 437.5 (Refer to Outline drawing). |
|
|
|
|
|
|
|
| ||||||||
4. | Vibration |
| – |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
5. | Shock |
| – |
| Less than 20G, half sine, 11mS. Units unpacked |
|
|
|
|
|
|
|
|
|
|
| |||||
2.11 SAFETY/EMC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1. | Applicable standards | Safety | – |
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| 60 < Vout < 400V: Output is hazardous, IEEE/Isolated analog are SELV |
|
|
|
| ||||||||||
|
|
|
|
|
|
| 400 < Vout < 600V: Output is hazardous, IEEE/Isolated, Analog are not SELV |
|
|
| |||||||||||
|
| EMC | – |
| EN55024 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2. | Withstand voltage |
| – |
| Vout < 60V models: |
|
|
|
|
|
| ||||||||||
|
|
|
|
| 60 ≤ Vout ≤ 600V models: |
|
|
| |||||||||||||
|
|
|
|
| Hazardous Output - SELV: 1.9KVrms 1 min, Hazardous |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
3. | Insulation resistance |
| – |
| More than 100Mohm at 25°C, 70%RH |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
4. | Conducted emission |
| – |
| EN55022B, FCC part |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
5. | Radiated emission |
| – |
| EN55022A, FCC part |
|
|
|
|
|
|
|
|
|
|
|
|
|
10