ES-2048 User’s Guide

Figure 101 Clustering Management Configuration

The following table describes the labels in this screen.

Table 66 Clustering Management Configuration

LABEL

DESCRIPTION

 

 

Clustering Manager

 

 

 

Active

Select Active to have this switch become the cluster manager switch. A cluster

 

can only have one manager. Other (directly connected) switches that are set to

 

be cluster managers will not be visible in the Clustering Candidates list. If a

 

switch that was previously a cluster member is later set to become a cluster

 

manager, then its Status is displayed as Error in the Cluster Management

 

Status screen and a warning icon ( ) appears in the member summary list

 

below.

Name

Type a name to identify the Clustering Manager. You may use up to 32 printable

 

characters (spaces are allowed).

VID

This is the VLAN ID and is only applicable if the switch is set to 802.1Q VLAN.

 

All switches must be directly connected and in the same VLAN group to belong

 

to the same cluster. Switches that are not in the same VLAN group are not visible

 

in the Clustering Candidates list. This field is ignored if the Clustering

 

Manager is using Port-based VLAN.

202

Chapter 27 Cluster Management