Se
t
sthe watchdog coun
t
. 0 turns
the watchdog off.
Sets the maximum (<high>) or
minimum (<low>) voltage at the
specified voltage sensor. You can
specify a voltage with up to three
digits after a decimal point (0.941
for example).
Normal voltage at each sensor: Idx:
1=1.0v, 2=1.8v, 3=3.3v, 4=2.4v
Sets the maximum (<high>) or
minimum (<low>) temperature at
the specified temperature sensor.
You can specify a temperature with
up to three digits after a decimal
point (-50.025 for example).
Temperature sensor locations: Idx:
1=DSL, 2=CPU, 3=power module
MSAP2000 AAMS User’s Guide
Table 58 Commands (continued)
COMMAND DESCRIPTION
set <msec|0:disable>
monitor
show Displays the hardware
monitor’s statistics.
enable Turns the hardware monitor on.
disable Turns the hardware monitor off.
vlimit <idx> <high>
<low>
tlimit <idx> <high>
<low>
showall [nopause] Displays all system-related
configuration.
adsl
show [portlist] Displays the ADSL settings.
enable <portlist> Turns on the specified ADSL ports.
disable <portlist> Turns off the specified ADSL ports.
profile
show [profile] Displays profile contents.