MSAP2000 AAMS User’s Guide

Table 59 Sys Commands (continued)

COMMAND

 

 

DESCRIPTION

 

 

sync

 

Retrieves the date and time from

 

 

 

 

the time server.

 

log

 

 

 

 

 

 

 

 

 

 

show

 

Displays the device’s logs.

 

 

 

 

 

 

 

clear

 

Clears the device’s logs.

 

 

 

 

 

 

wdog

 

 

 

 

 

 

 

 

 

 

show

 

Displays the current watchdog

 

 

 

 

firmware protection feature status

 

 

 

 

and timer.

 

 

set

<msec0:disable>

Sets the watchdog count. 0 turns the

 

 

 

 

watchdog off.

 

monitor

 

 

 

 

 

 

 

 

 

 

show

 

Displays the hardware monitor’s

 

 

 

 

statistics.

 

 

enable

 

Turns the hardware monitor on.

 

 

disable

 

Turns the hardware monitor off.

 

 

 

 

 

 

 

vlimit

<idx> <high>

Sets the maximum (<high>) or

 

 

 

<low>

minimum (<low>) voltage at the

 

 

 

 

specified voltage sensor. You can

 

 

 

 

specify a voltage with up to three

 

 

 

 

digits after a decimal point (0.941 for

 

 

 

 

example).

 

 

 

 

Normal voltage at each sensor: Idx:

 

 

 

 

1=1.0v, 2=1.8v, 3=3.3v, 4=2.4v

 

 

tlimit

<idx> <high>

Sets the maximum (<high>) or

 

 

minimum (<low>) temperature at

 

 

 

<low>

the specified temperature sensor.

 

 

 

 

You can specify a temperature with

 

 

 

 

up to three digits after a decimal

 

 

 

 

point (-50.025 for example).

 

 

 

 

Temperature sensor locations: Idx:

 

 

 

 

1=DSL Line Driver, 2=DSL Chipset,

 

 

 

 

3=CPU

 

showall

[nopause]

 

Displays all system-

 

 

 

 

related configuration.

25.2 Sys Command Examples

These are the commonly used commands that belong to the sys (system) group of commands.

25.2.1Info Show Command

Syntax:

ras> sys info show

156

Page 156
Image 156
ZyXEL Communications MSAP2000 manual Sys Command Examples, Info Show Command, Syntax, Set Msec0disable, =Cpu