ras> adsl alarmprofile show DEFVAL 01. DEFVAL

 

 

ATU-C

ATU-R

 

 

----------

- ---------

Thresh15MinLofs

(sec):

0

0

Thresh15MinLos

(sec):

0

0

Thresh15MinLols

(sec):

0

---

Thresh15MinESs

(sec):

0

0

ThreshFastRateUp

(bps):

0

0

ThreshInterleaveRateUp

(bps):

0

0

ThreshFastRateDown

(bps):

0

0

ThreshInterleaveRateDown

(bps):

0

0

InitFailureTrap(1-enable, 2-disable):

 

2

---

Thresh15MinFailedFastRetrain:

 

0

---

Thresh15MinSes (sec):

 

0

0

Thresh15MinUas

(sec):

0

0

26.3.15Alarm Profile Set Command

Syntax:

adsl alarmprofile set <profile> [<atuc lofs> <atur lofs> <atuc loss> <atur loss> <atuc lols> <atuc lprs> <atur lprs> <atuc ess> <atur ess> <atuc fast rateup> <atur fast rateup> <atuc interleave rateup> <atur interleave rateup> <atuc fast ratedown> <atur fast ratedown> <atuc interleave ratedown> <atur interleave ratedown> <init fail enable> <atuc ses> <atur ses> <atuc uas> <atur uas>]

where

<profile>

atuc traffic)

atur

<atuc lofs> <atur lofs>

<atuc loss> <atur loss>

<atuc lols>

<atuc lprs> <atur lprs>

=A name for the alarm profile (up to 31 ASCII characters). Upstream. These parameters are for the connection (or

coming from the subscriber’s device to the MSAP2000 AAMS.

Downstream. These parameters are for the connection (or traffic) going from the MSAP2000 AAMS to the subscriber’s device.

=The number of Loss Of Frame Seconds that are permitted to occur within 15 minutes.

=The number of Loss Of Signal Seconds that are permitted to occur within 15 minutes.

=The number of Loss Of Link Seconds that are permitted to occur within 15 minutes

=The Number of times a Loss of PoweR is permitted to occur (on the ATUR) within 15 minutes.