MSAP2000 AAMS User’s Guide

Figure 120 VLAN Frame Type Command Example

ras> switch vlan frametype 3 tag

27.8.9 VLAN CPU Show Command

Syntax:

switch vlan cpu show

This command displays the management VLAN (CPU). You can only use ports that are members of this management VLAN in order to manage the MSAP2000 AAMS.

27.8.10VLAN CPU Set Command

Syntax:

switch vlan cpu set <vid>

where

<vid>

= The VLAN ID. Valid parameter range = [1 – 4094].

This must be the VLAN ID of a VLAN that is already configured. The VLAN must also have at least one port set to the fixed status.

This command sets the management VLAN (CPU). You can only manage the MSAP2000 AAMS through ports that are members of the management VLAN.

Note: By default, you can access the management VLAN from all the Ethernet and ADSL ports since they are all in the management VLAN). If you need more security, please see the following example.

27.8.11Configuring Management VLAN Example

Note: After the following example configuration, you must connect to the first Ethernet port through a VLAN aware device that is using the proper VLAN ID in order to perform management.

By default, the MSAP2000 AAMS’s ADSL ports are members of the management VLAN (VID 1). The following procedure shows you how to configure a tagged VLAN that limits management access to just one Ethernet port.

Note: Use the console port to configure the MSAP2000 AAMS if you misconfigure the management

VLAN and lock yourself out.

207