119
MSAP2000 AAMS User’s Guide

18.3.3 ZyXEL Private MIB SNMP Traps

The MSAP2000 AAMS can also send the following SNMP traps that are defined in

the ZyXEL private

MIBs.

Table 45 ZyXEL Private MIB SNMP Traps
TRAP DESCRIPTION
sendThermoFailureTrap This trap is sent when the hardware monitor chip has failed.
sendVoltageOutOfRange This trap is sent periodically when the MSAP2000 AAMS’s voltage is
outside of the Trap accepted operating range.
sendVoltageNormalTrap This trap is sent when the MSAP2000 AAMS is no longer
outside of the accepted operating range.
sendOverHeatTrap This trap is sent periodically when the MSAP2000 AAMS is overheated.
sendOverHeatOverTrap This tr ap is sent when the MSAP2000 AAMS is no longer ov erheated.
sendRebootTrap This trap is sent each time the MSAP2000 AAMS restarts.
18.3.4 Configuring SNMP

Click Advanced Application and Access Control from the navigation panel and

then SNMP from the Access Control screen to open the following screen.

Figure 57 Access Control: SNMP