MSAP2000 AAMS User’s Guide

where

<idx>

= The index number of the sensor that can detect and

 

report the voltage.

<high>

= The maximum voltage limit at a sensor.

 

You can specify a voltage with up to three digits after a

 

decimal point (0.941 for example).

<low>

= The minimum voltage limit at a sensor.

 

You can specify a voltage with up to three digits after a

 

decimal point (0.941 for example).

This command sets the maximum and minimum voltage at a voltage sensor.

The following example sets the highest (1.242) and the lowest (1.035) voltage limit at the first sensor.

Figure 89 Monitor Vlimit Command Example

ras> sys monitor vlimit 1 1.242 1.035

25.2.22 Monitor Tlimit Command

Syntax:

ras> sys monitor tlimit <idx> <high> <low>

where

<idx>

= The index number of the temperature sensor that can

 

detect and report the temperature.

<high>

= The maximum temperature limit at a sensor.

 

You can specify a temperature with up to three

 

digits after a decimal point (-50.025 for example).

<low>

= The minimum voltage limit at a sensor.

 

You can specify a temperature with up to three

 

digits after a decimal point (-50.025 for example).

The following example sets the highest (97.0) and the lowest (-55.0) temperature limit at the first sensor.

166

Page 166
Image 166
ZyXEL Communications MSAP2000 manual Monitor Tlimit Command