ZyXEL Communications MSAP2000 manual Log Show Command

Models: MSAP2000

1 248
Download 248 pages 50.78 Kb
Page 164
Image 164

MSAP2000 AAMS User’s Guide

where

 

[none]

= This sets the system to not use a time server.

<daytimetimentp>

= The time service protocol.

 

<daytime> When you select the Daytime (RFC 867) format,

 

the switch displays the day, month, year and time with no

 

time zone adjustment. When you use this format it is

 

recommended that you use a Daytime timeserver within

 

your geographical time zone.

 

<time> Time (RFC-868) format displays a 4-byte integer

 

giving the total number of seconds since 1970/1/1 at 0:0:0.

 

<ntp> NTP (RFC-1305) is similar to Time (RFC-868).

<ip>

= The IP address of the time server.

<utc[<+->

= The time difference between UTC (Universal Time

0100~1200]>

Coordinated, formerly known as GMT, Greenwich Mean

 

Time) and your time zone.

[nosync]

= This sets the system to not synchronize with the

 

time server immediately after you press [Enter].

This command sets the MSAP2000 AAMS to use a time server.

The following example sets the MSAP2000 AAMS to use Daytime protocol to access a time server at IP

address 192.50.77.164 and sets the MSAP2000 AAMS’s time zone to UTC.

Figure 86 Time Server Set Command Example

ras> sys timeserver set daytime 192.50.77.164 utc

25.2.18Log Show Command

Syntax:

ras> sys log show

This command displays the system error log.

An example is shown next.

164

Page 164
Image 164