Schneider Electric
Official User Manual for LUFP7 Gateways by Telemecanique
Communication Characteristics
Install
Signalling
Description of the error
ABC Configurator
Diagnostic length
IEC61915 command register
NAD 911 04 or 03 connector
Powering the Gateway
Service PLC input Description
Page 1
LUFP7
Telemecanique
User’s manual
Gateway
Profibus-DP /
Modbus RTU
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
LUFP7
Page
LUFP9
Page
Table of Contents
Introduction to the User Guide
Introduction
Terminology
Introduction to the LUFP7 Gateway
DPM1
Notational Conventions
Introduction to the Communication System Architecture
Additional Documentation
Profibus-DP Master Upstream network Profibus-DP
Modbus
Principle Used to Configure and Operate the LUFP7 Gateway
Modbus Network
ABC Configurator
Hilscher
LUFP7 gateway
Profibus-DP
Hardware Implementation of the LUFP7 Gateway
Configuration Modbus RTU
On Receipt
Mounting the Gateway on a DIN Rail
Powering the Gateway
Mounting the gateway
LU9GC03
Connecting the Gateway to the Modbus Network
Examples of Modbus Connection Topologies
LUFP7 Gateway
Pin Outs
TSXCSA00
120 Ω
Wiring Recommendations for the Modbus Network
Hubs, drops, taps, and line terminations
NAD 911 04/03 connector Point SUB-D male
Connecting the LUFP7 gateway to the Profibus-DP Network
Cables
Pin Outs LUFP7 plug --- 9-point SUB-D female
GND
Wiring Recommendations for the Profibus-DP Network
NAD 911 04 or 03 connector
Encoding the Gateway Address
Configuring the Profibus-DP Communication Features
No Internal Line Termination Address =
Signalling
Introduction
Software Implementation of the Gateway
System Architecture
Profibus-DP
Modbus Cycle Time
Configuring the Motor Starters
Managing Degraded Modes
Setting Up the Hardware Configuration under PL7 PRO
Gateway Configuration under PL7 PRO and SyCon
Selecting and Adding the Profibus-DP Master Station
Creating a Profibus-DP Network under SyCon
Setting up the Gateway Description Files
Selecting and Adding the Gateway to the Profibus-DP Network
Editing and Configuring the Gateway
Software Implementation of the Gateway
Diagnostic length
Saving and Exporting the Profibus-DP Network Configuration
Optional
Possible values
Configuring the Gateway I/O under PL7 PRO
Service PLC output Description
Service PLC input Description
IW4.0
IW4.0.1
Sample reading of a motor starter parameter
Description of Services Assigned to Gateway Inputs/Outputs
Allocating Symbols to the Gateway Inputs and Outputs
Developing a Profibus-DP Application
Using and Monitoring the TSX PBY 100 Coupler Configuration
Disabled 5.3.2 Profibus-DP Master Control Word
Gateway Initialization and Diagnostics
Full Management
Control/Status Byte field
Profibus-DP Master Control Word
Fbdu Modbus exchange startup
11EC Error code associated with the Modbus network
Bits Description Abchssend New gateway diagnostic
ED Error data item associated with the Modbus network
Gateway Status Word
Description of the error
Diagnostic Only
Bits Description Abcdu Modbus exchanges activated
Simplified Operation
Connecting the Gateway to the Configuration PC
Configuring the Gateway
RS-232 Link Protocol
GND
Importing the Gateway Configuration
Installing AbcConf
Monitoring the Content of the Gateway’s Memory
Transferring a Configuration to the Gateway
Configuring the Gateway
Deleting a Modbus Slave
Procedure for deleting a Modbus slave
Adding a Modbus Slave
Copying a previously configured Modbus slave
Adding a new type of Modbus slave
Importing/exporting a Modbus slave configuration
Replacing a periodic input data element
Changing the Periodic Data Exchanged with a Modbus Slave
Replacing an Output Periodic Data Element
Increasing the Amount of Periodic Input Data
Configuring the Gateway
Configuring the Gateway
Configuring the Gateway
IW4.0.17
IW4.0.16
IW4.0.18
IW4.0.19
Configuring the Gateway
Configuring the Gateway
Configuring the Gateway
Configuring the Gateway
QW4.0.16
Deleting Aperiodic Parameter Data
QW4.0.17
Configuring the Gateway
Configuring the Gateway
Managing the downstream
Changing the name of a Modbus slave
Changing a Modbus Slave Configuration
Changing the Address of a Modbus slave
With the TeSys U Motor Starters
Adding and Setting Up a Modbus Command
Modbus response
Name of the Modbus command Modbus query
With a Generic Modbus Slave
CPU stop/failure LUFP7 gateway Profibus-DP Modbus RTU
Configuration Description Element
Configuring the Query
Configuring the Gateway
Default communication mode. The query is transmitted
Configuring the Response
Configuring the Content of the Query Frame
Field Size Description Frame
Configuring the Content of the Response Frame
Mode. The default value, CRC, should not be changed
Start byte fields
Modbus Commands Based on Standard Commands
Adding a Special Modbus Command
Modbus Commands which Can Be Completely Changed by the User
Fieldbus Element
Configuring the General Characteristics of the Gateway
ABC Element
Sub-Network Element
Configuring the Gateway
Adding a Broadcaster Node
Communication Characteristics
Appendix a Technical Characteristics
Environment
Communications between other stations Performance Results
Inputs
General data
Appendix B LUFP7 Gateway GSD File
GSD File Content
Identification Number
Identification number Name of the related GSD file
Maximum response time of the gateway
Input
Appendix C Default Configuration
16#10
Configuring Modbus Exchanges
16#06
Service Address Size Description
Content of the Gateway’s Dpram Memory
Input Data Memory Area
Output Data Memory Area
Overview of the LUFP7 Tutorial Example
Appendix D Sample Use under PL7 PRO
LUFP7 Gateway Initialization and Diagnostics
See note
Controlling and Supervising the 8 TeSys U Motor Starters
IEC61915 command register
TeSys U status register IEC61915
Reading and Writing any TeSys U Motor Starter Parameter
Appendix D Sample Use under PL7 PRO
Appendix D Sample Use under PL7 PRO
Gateway Profibus-DP Diagnostics
Appendix E Profibus-DP Data and Diagnostics
Bytes Structure Description
Bytes Name Description
Gateway Configuration Data
Bytes Name Value
General Gateway Information
108
Appendix F Modbus Commands
Preset Single Register Command 16#06
Read Holding Registers Command 16#03
Frame Field Value or properties
Modbus Protocol Exception Responses
Preset Multiple Registers Command 16#10
Code Name Description of the exception Exception
LUFP7 Quantum
Appendix F Concept and Quantum PLC
Left intentionally blank 114
Page
User’s Manual LUFP7 V1.1 2003-05
Related pages
Troubleshooting Guide for GE 906
Technical Specifications for D-Link DI-624
Error Messages Operator Call Service Messages 124 for Konica Minolta 2530 DL
Assembly Diagram for Harbor Freight Tools 97181
HOW to USE Heart Rate Programs for ProForm PFTL59822
WinXP Treiber deinstallieren for Microsoft 63XPL/PS
Replacement Parts List for Pentair D.E. Cartridge Style Filter
Language code list for Samsung HT-E350K/UM
Leds Alarms & Switches for Tripp Lite OMNI1500XLNAFTA
What are the available
WEP Key types for TP-Link TL-ER604W
?
Top
Page
Image
Contents